文章从独立新风系统、净化空调系统及手术室内排风系统,介绍了太和县人民医院洁净手术室的空调系统的设计,并就设计中应注意的室内压力、回风口与排风口的设置、新风与排风过滤器的设置等问题谈了几点体会。
The article introduces air conditioning design for OR of Taihe People's Hospital which consists of an isolated air blowing system, an air clearting system and an air exhausting system in OR; and then discusses several points that should be noticed in the design process such as the interior pressure, setting of the return-air intake and the air outlet as well as setting of the fihers for fresh air and exhaust air etc.
出处
《安徽建筑》
2008年第3期153-154,共2页
Anhui Architecture
关键词
洁净空调系统
洁净度
正压
整体控制
气流分布
clean air conditioning system
cleanness
positive pressure
general control
air flow distribution