摘要
在土木建筑工程中,钢筋混凝土结构裂缝的产生是多方面原因引起的。工程技术人员(包括设计及施工)只有通过不断总结经验,并根据不同的客观环境因素,制定相应的防护措施,那么,裂缝这一破坏现象总可以得到避免的。该文就某污水处理厂污水池壁连续墙裂缝产生的原因作一分析,以供同行在今后类似工程中参考。
In the civil engineering,the crack of the steel reinforced concrete structure is caused by many aspects. Only if the engineering technical members (including the design and construction) continuously sum up the experience and work out the relative protective measures on the different objective environmental factors,this destroying appearance of the crack can be avoided. The article analyzes the cause of the crack on the continuous wall of the sewage tank in a wastewater treatment plant. Its aim is to provide the reference for the similar projects in the future.
出处
《城市道桥与防洪》
2008年第6期61-62,共2页
Urban Roads Bridges & Flood Control
关键词
钢筋混凝土
污水池壁
裂缝分析
steel reinforced concrete,sewage tank wall,crack analysis