期刊文献+

术中经食管超声心动图在全机器人房间隔缺损修补术中的作用 被引量:2

The importance of intraoperative transesophageal echocardiography in totally endoscopic atrial septal defect repair with robotic assistance
原文传递
导出
摘要 目的探讨术中经食管超声心动图(TEE)在全机器人房间隔缺损(ASD)修补术中的作用。方法对24例拟行全机器人ASD修补术的患者进行前瞻性研究。全身麻醉诱导及双腔气管插管后,将TEE探头插入食管中段。①体外循环转机前,进一步明确ASD类型、数目及大小;术者参考上述信息初步拟定手术方案。②建立体外循环时,在TEE引导下,经右股静脉插入-19F或21F股静脉插管至下腔静脉一右心房连接处;经皮经右颈内静脉插入-15F或17F股动脉插管至上腔静脉;于第二肋间经皮将-14G心脏停搏液灌注针插入升主动脉管腔中央偏后、距主动脉瓣口约3cm处。③心脏复跳后,应用TEE即刻评价房间隔水平有无残余分流及有无手术相关并发症。结果①以手术结果为标准,TEE诊断ASD类型、数目的准确性为100%;所有患者修补ASD均按术前拟定方案进行。②术中证实,所有患者下、上腔静脉内插管及升主动脉内灌注针均放置于适当位置,TEE引导置管成功率为100%。③心脏复跳后,TEE显示所有患者房间隔水平均无残余分流,均无手术相关并发症。结论术中TEE在全机器人ASD修补术中必不可少。 Objective To explore the importance of intraoperative transesophageal echocardiography(TEE) in totally endoscopic atrial septal defect(ASD) repair. Methods Twenty four patients underwent repair of ASD by a totally endoscopic approach,utilizing the da Vinci S robotic system. After induction of general anesthesia and a left-sided double-lumen endotracheal tube was positioned, a TEE probe was inserted. ①Before cardiopulmonary bypass(CPB) ,TEE examination was conducted to document the types and size of ASD. The procedures were predetermined by the operator according to the TEE diagnosis. ②CPB was achieved peripherally. With TEE guidance,a 19-or 21-Fr. femoral venous cannula was inserted into the right common femoral vein and passing it into the inferior vena cava(IVC) ,with its tip just inferior to the IVC-right atrium junction;a 15- or 17-Fr. femoral arterial cannula was placed percutaneously into the right internal jugular vein and passed into the superior vena cava(SVC). The bypass circuit was completed by inserting a 14G arterial perfusion cannula into the ascending aorta(AAO) ,with its distal tip passing over the center of the AAO,approximately 3 cm from the aortic valve. ③ After weaning from CPB,TEE examination was performed again. Results ①Surgical confirmation was obtained in all the patients and no operative procedures were changed.②All venous, arterial and arterial perfusion cannula were located in correct position.③In all patients, TEE after weaned from CPB confirmed successful repair. Conclusions Intraoperative TEE is essential for totally endoscopic ASD repair.
出处 《中华超声影像学杂志》 CSCD 2008年第6期461-464,共4页 Chinese Journal of Ultrasonography
关键词 超声心动描记术 经食管 房间隔缺损 外科手术 微创性 Echocardiography, transesophageal Heart septal defects, atrial Surgical procedures, minimally invasive
  • 相关文献

参考文献7

  • 1Rose M, Ponsky J. Minimally invasive surgery. Endoscopy,2001, 33:358-366.
  • 2Camarillo DB, Krummel TM ,Salisbury JK, et al. Robotic technology in surgery: past, present, and future. Am J Surg, 2004, 188 (4A Suppl) :2S-15S.
  • 3Shanewise JS, Zaffer R. Martin RP, et al. Intraopcrative echocardiography and minimally invasivc cardiac surgery. Echocardiography, 2002,19 : 579-582.
  • 4徐平.微创心脏外科学.北京:人民卫生出版社,2007.397-411.
  • 5孔博,张秀和.机器人辅助心脏手术的临床应用进展[J].中华胸心血管外科杂志,2005,21(2):121-122. 被引量:2
  • 6Sznajder Jl, Zveibil FR, Bitterman H, et al. Central vein catherization:failure and complication rates by three percutaneous approaches. Arch Intern Med, 1998,146:259-261.
  • 7Andropoulos DB, Stayer SA, Bent ST, et al. A controlled study of transesophageal echocardlography to guide central venous catheter placement in congenital heart surgery patients. Andropoulos Anesth Analg, 1999,89 : 65-70.

二级参考文献13

  • 1Carpentier A, Loulmet D, Aupecle B, et al. Computer assisted open heart surgery. First case operated on with success. C R Acad SCI III, 1998,321:437-442.
  • 2Chitwood WR Jr, Nifong LW, Elbeer JE, et al. Robotic mitral valve repair: tra-pezoidal resection and prosthetic annuloplasty with the da Vinci surgical system. J Thorac Cardivas Surg, 2000,120:1171-1172.
  • 3Mehmanesh H, Henze R, Lange R, et al. Totally endoscopic mitral valve repair. J Thorac Cardiovasc Surg,2002,123:96-97.
  • 4Le Bret E, Papadatos S, Folliguet T, et al. Interruption of patent ductus arteriosus in children: robotically assisted versus videothoracoscopic surgery. J Thorac Cardiovasc Surg,2002,123:973-976.
  • 5Argenziano M, Oz MC, Kohmoto T, et al. Totally endoscopic atrial septal defect repair with robotic assistance. Circulation, 2003,108(Suppl 1):II191-194.
  • 6Otero TF,Cortes MT. Artificial muscles with tactile sensitivity. Adv Master Weinheim, 2003,15:279-282.
  • 7Mohr FW, Falk V, Diegeler A, et al. Computer-enhanced coronary artery bypass surgery. J Thorac Cardiovasc Surg, 1999,117:1212-1213.
  • 8Loulmet D, Carpentier A, Attellis N, et al. Endoscopic coronary artery bypass grafting with the aid of robotic assisted instruments. J Thorac Cardiovasc Surg, 1999,118:4-10.
  • 9Boyd WD,Rayman R,Desai ND,et al.Closed-chest coronary artery bypass grafting on the beating heart with the use of a computer-enhanced surgical robotic system. J Thorac Cardiovasc Surg,2000,120:807-809.
  • 10Mohr FW, Falk V, Diegeler A, et al. Computer-enhanced "robotic" cardic surgery: experience in 148 patients. J Thorac Cardiovasc Surg,2001,121:842-853.

共引文献3

同被引文献11

  • 1Bonow gO, Carabello BA, Chatterjee K, et al. ACC/AHA 2006 guidelines for the management of patients with valvular heart disease: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (writing Committee to Revise the 1998 guidelines for the management of patients with valvular heart disease) developed in collaboration with the Society of Cardiovascular Anesthesiologists endorsed by the Society for Cardiovascular Angiography and Interventions and the Society of "Ihoracic Surgeons [J].J Am Coil Cardiol, 2006, 48 (3): e1-148.
  • 2Lehr EJ, Rodriguez E, Chitwood WR. Robotic cardiac surgery[J]. Curr Opin Anaesthesiol, 2011, 24 (1): 77-85.
  • 3Sheikh KH, de Bruijn NP, Kankin JS, et al. The utility of transesophageal echocardiography and Doppler color flow imaging in patients undergoing cardiac valve surgery[J].J Am CoU Cardiol, 1990, 15 (2): 363-372.
  • 4Khandheria BK, Taiik AJ, Seward JB. Multiplane transesophageal echocardiography-examination technique, anatomic correlations, and image orientation [J]. Critical Care Clinics, 1996,12 (2): 203-233.
  • 5Wang Y, Gao CO, Wang JL, et al. The Kole of Intraoperative transesophageal echocardiography in robotic mitral valve repair[J]. Echocardiography, 2011, 28 (1): 85-91.
  • 6Jeanmart H, Casselman FP, De Grieck Y, et al. Avoiding vascular complications during minimally invasive, totally endoscopic intracardiac surgery[J]. J Thorac Cardiovasc Surg, 2007, 133 (4): 1066-1070.
  • 7Kypson AP, Nifong LW, Chitwood WK, et al. Robotic mitral valve surgery[J]. Semin Thorac Cardiovasc SurF,, 2003, 15 (2): 121-129.
  • 8Shapira Y, Vaturi M, Weisenberg D, et al. Intraoperative transesophageal echocardiography during valve replacement surgery. A review[J]. Minerva Cardioangiol, 2007, 55 (2): 229-237.
  • 9Rosenhek R, Binder T, Maurer G. Intraoperative transesophageal echocardiography in valve replacement surgery[J]. Echocardiography, 2002, 19 (8): 701-707.
  • 10张烁,郭文彬,李红昕.经食管超声心动图监测微创室间隔缺损封堵术[J].中国介入影像与治疗学,2012,9(2):103-106. 被引量:5

引证文献2

二级引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部