期刊文献+

超常视力眼波前像差与对比度视力相关性研究 被引量:1

Relation Of ocular wavefront aberrations and visual acuity at different contrast levels innatural super visual acuity eyes
原文传递
导出
摘要 目的分析超常视力眼波前像差与不同对比度视力的相关关系,探讨与视力相关的像差函数。方法应用Snellcn视力表检测裸眼视力≥1.5者81例(81只眼),用WASCA波阵面像差仪测眼波前像差,用多功能电子视力测量仪测量、暗环境下对比度分别为100%、25%、10%和5%的视力。用多元线性相关与回归分析波前像差与不同对比度视力的相关关系。结果总像差、各阶像差及各Zernike函数与亮、暗环境中对比度为100%和25%视力间的直线相关关系均无统计学意义(P〉0.05)。总像差、2阶像差及离焦像差与亮、暗环境中对比度为10%和5%视力间直线相关关系均有统计学意义(P〈0.01)相关系数分别为-0.30、-0.35和-0.28、-0.35:-0.33、-0.38和-0.28、-0.39;-0.31、-0.39和-0.28、-0.39(P〈0.01)。其余像差与对比度为10%利5%视力间直线相关关系均无统计学意义(P〉0.05)。结论超常视力眼波前像差与高对比度视力无直线相关关系,与低对比度视力有直线相关关系,总像差、2阶像差和离焦像差越小,低对比度视力越好。 Objective To investigate the relation between ocular wavefront aberration and visualacuity at different contrast level in natural super visual acuity eyes.Methods 81 eyes of 81people with uncorrected visual acuity ≥ 1.5 using Snellen visual acuity Chart were enrolled in thisstudy.Ocular aberration was measured using a Hartmann-Shack wavefront analyzer.Visual acuityat 100%, 25%, and 10 %, and 5 % contrast level under mesopic and scotopic condition was measuredusing a computer generated muti-function-visual-acuity an- alyzer.Linear correlation was used to analyze the relation between ocular wavefront aberration and visual acuity at different contrastlevel.Resuls Linear correlation;analysis revealed that the total aberration root-mean-square (RMS) ,the 2-7 order RMS,and each Zernike coefficient was not significantly correlated withvisual acuity at 100 %, 25 % contrast level under mesopic and scotopic condition(P 〉0.05 ).Thetotal RMS, the 2nd order RMS, and tile delbcus coefficient was significantly correlated withvisual acuity at 10 %, 5 % contrast level under mesopic and scotopic condition (P 〈0.01 ),and thecorrelation coefficient was-0.30,-0.35 and-0.28 ,-0.35 : -0.33,-0.38 and-0.28, -0.39 : -0.31, -0.3 and -0.28, -0. : 39 respectively.The 3-7 order RMS, and the other Zernikecoefficient except defocus was not significantly correlated with visual acuity at 10 %, 5 % contrastlevel under mcsopic and scotopic condition(P 〉0.05 ).Conclusions In natural surer visual acuityeyes, the ocular waveffont aberrations were not significantly correlated with visual acuity athigh contrast level, but were significantly correlated with visual acuity at low contrast levels.Thetotal aberration RMS, 2rd order RMS, and defocus coefficient were more lower, the visual acuityat low contrast level were more better.
出处 《中国实用眼科杂志》 CSCD 北大核心 2008年第6期569-572,共4页 Chinese Journal of Practical Ophthalmology
关键词 视力 对比度 波前像差 Visual acuity Contrast sensitivity Aberration
  • 相关文献

参考文献11

  • 1Levy, Segal O, Avni I, et al D.ocular higher-order aberrations in eyes with supernormal vision.Amj Ophthahnol , 2005,139 : 225-8.
  • 2Mallner L.Martin L.Microdot test of foveal function.A comparison with visual acuity at high and low contrast.ophthahnic Physiol Opt, 2005,25(2) : 81-6.
  • 3Applegate RA, Marsack JD,Thibos LN Metries of retinal image quality predict visual performance in eyes with 20/17 or better visual acuity. Optom Vis Sci, 2006,83(9) : 635-40.
  • 4Bailey MD.Olson MD,Bullimore MA,et al.The effect of LASIK on best-correeted high-and low-contrast visual acuity.Optoln Vis Sci, 2004,81(5):362-8.
  • 5Rajagopalan AS,Bennett ES,Lakshminarayanan V Visual performance of subjects wearing presbyopic contact lenses.Optom Vis Sci, 2006,83(8) :611-5.
  • 6Oshika T,Okamoto C,Samejima T,et al.Contrast sensitivity function and ocular higher-order wavefront aberrations in normal human eyes.Ophthalmology, 2006,113 ( 10) : 1807-1812.
  • 7Tanabe T, Miyata K, Samejima T, et al.Influence of wavefront aberration and corneal subepithelial haze On low-contrast visual acuity after photorefractive keratectomy.Am J Ophthalmol,2004t, 138(4) :620- 624.
  • 8Oshika T Tokunaga T,Samejima,T:et al. Influence of pupil diameter On the relation between ocular highm-order aberration and contrast sensitivity after laser in Situ keratomileusis.Invest Ophthalmol Vis Sei, 2006,47(4) : 1334-1338.
  • 9Thibos LN, Applegate RA, Schwiegerling,JT.Webb R&VSIA Standards Taskforce Members.Standards for reporting the optical aberrations of eye.Refract Surg, 2002, 18 : 652-660.
  • 10Strang NC, Atchison DA, Woods RL.Effects of defocus and pupil size on human contrast sensitivity.Ophthalmic Physiol Opt, 1999,19 (5) : 41 5-426.

同被引文献14

  • 1史胜,柳林,周行涛,鲍兰,肖其瑞.正常人亮暗背景下不同对比度的视力变化[J].第二军医大学学报,2007,28(7):714-717. 被引量:9
  • 2Miller D.Optics and refraction[M].New York:Gower MedicalPublishing,1991.15-23.
  • 3Campbell FW,Robson JG.Application of fourier analysis to thevisibility of gratings[J].J Physiol,1968,197(3):55l-566.
  • 4Wooten BR,Renzi LM,Moore R,et al.A practical method ofmeasuring the human temporal contrast sensitivity function[J].Biomed Opt Express,2010,.
  • 5Norcia AM,Tyler CW,Hamer RD.Development of contrast sen-siticity in the human infant[J].Vision Res,1990,30(10):1475-1486.
  • 6Nassi JJ,Callaway EM.Multiple circuits relaying primate oarallelvisual pathways to the idle temporal area[J].J Neurosci,2006(12):789-798.
  • 7Matinez CE,Applegate RA,Klyce SD,et al.Effect of pupillarydiameter on corneal optical aberrations after photorefractive ke-ratectomy[J].Arch.
  • 8Liang JZ,Willias DR.Aberrations and retinal image quilaty ofthe normal human eye[J].J Opt Soc Am,1997,14(24):2873-2883.
  • 9Mrochen M,Seiler T.Influence of corneal curvature on cal-culation of ablation patterns used in photorefractive laser sur-gery[J].Refract Su.
  • 10Levy,Segal 0,Avni I,et al D.Ocular higher-order aberrationsin eyes with supernormal vision[J].Am J Ophthahnol,2005,139(3):225-8.

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部