期刊文献+

光纤图像分割器的透过率分析与测试 被引量:3

The Analysis and Testing on the Transmission Rate of the Fiber-optic Image Slicer
下载PDF
导出
摘要 以1×2(输入端为一列2 000根光纤,输出端为两列1 000根光纤)光纤图像分割器为例,分析了器件在传输图像过程中产生的四种损耗(吸收损耗、全反射损耗、散射损耗、端面菲涅耳损耗),并在理论上计算出以波长λ=632.8 nm的H e-N e激光做光源时器件的整体透过率为54.56%,与实验所测值51.46%基本吻合,从而证明了自行设计测试装置的可行性。最后给出了提高光纤图像分割器透过率需遵循的基本原则。 High transmission rate of the fiber-optic slicer is decisive to its application in spectrograph. As an example, the 1× 2 fiber-optic imager slicer is developed and four types of loss occurred during light signals transmitting is analyzed. At the wavelength of 632.8 nm emitted by He-Ne laser, the transmission rate of the device is tested to be 51.46~, which is near to 54. 56~/4o calculated based on the principle of light transmitting considering the four types of loss mentioned above. Thus the testing system is proved to be feasibility. The rule of how to improve the transmission rate of the fiber-optic is given eventually.
出处 《光电子技术》 CAS 2008年第2期93-96,100,共5页 Optoelectronic Technology
基金 应用光学国家重点实验室开放基金资助
关键词 光纤图像分割器 透过率 损耗 测试 fiber-optic imager slicer transmission rate loss testing
  • 相关文献

参考文献8

  • 1Iye Masanori, Ebizuka Noboru, Takami Hideki. Fiber pupil slieer-A versatile light feed for spectrographs [J]. SPIE, 1998,3 355:417-423.
  • 2David William Fletcher-Holmes, Andrew Robert Harvey. A snapshot foveal hyper-spectral imager [J]. SPIE, 2002, 4 816:407-414.
  • 3Lin Haosheng, Alex Versteegh. VisIRIS-A visible/IR imaging spectropolarimeter based on a birefringent fiber-optic image slicer[J]. SPIE, 2006,6 269:62690k-1-62690k-11.
  • 4梁静秋,侯凤杰.采用硅V型槽的一维光纤阵列的研制[J].光学精密工程,2007,15(1):89-94. 被引量:20
  • 5郑玉权.一种采用光纤变维器的长线阵探测器拼接方法及装置:中国,200510016818.3[P].2005-11-09.
  • 6朱云青,徐明泉,赵锦琳.光纤束光透过率影响因素[J].玻璃纤维,2005(6):12-15. 被引量:4
  • 7廖延彪.光纤光学[M].北京:清华大学出版社,2001..
  • 8胡敏,周汉昌,陈闽鄂,王高.光纤传像器件参数测试方法研究[J].中北大学学报(自然科学版),2006,27(6):533-536. 被引量:3

二级参考文献7

共引文献35

同被引文献33

引证文献3

二级引证文献18

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部