期刊文献+

火焰原子吸收法测定土壤中的铜铅 被引量:7

Study on Determination of Copper and Leader in Soil by Flame Atomic Absrption Spectrometry
下载PDF
导出
摘要 研究了用火焰原子吸收法测定土壤中铜铅的最佳实验条件及其测定方法。通过对2种消解体系(硝酸-氢氟酸-双氧水体系,硝酸-氢氟酸-高氯酸体系)的对比,得出了铜铅的最佳消解方法为硝酸-氢氟酸-双氧水体系。通过对标准样品的多次测定,测定值均在其保证值范围内,铅相对标准偏差为1.3%~6.5%,加标回收率为94%~104%;铜相对标准偏差为3.6%~5.1%,加标回收率为93%~106%。该方法步骤简便、省时、省试剂,结果令人满意。 In this paper, a method was developed for the determination of copper and leader in soil by flame atomic absorption spectrometry(FAAS) ,the best expedmental condition was studied. Through comparison of two counteraction systems (HNO3-FH-H2O2 system and HNO3-HF-HClO4 system) , the best counteraction system is HNO3-HF-HClO4 system. It has been showed the relative standard error of 1.3%-6.5% and a recovery of 93% -107% for Pb;whereas a relative standard error of 3.6%-5.1% and a recovery of 93%-104% belong to Cu. This method is simple, quick, regent-saving and has a satisfying result .
作者 徐学笛
出处 《当代化工》 CAS 2008年第3期333-335,共3页 Contemporary Chemical Industry
关键词 火焰原子吸收法 土壤 Flame atomic absorption spectrometry(FAAS) Soil Copper Lead
  • 相关文献

参考文献7

二级参考文献4

  • 1国家环境保护局《水和废水监测分析方法》编委会.水和废水监测分析方法(第4版)[M].北京:中国环境科学出版社,2002..
  • 2魏复盛 齐文启.原子吸收及其在环境化学中的应用[M].中国环境科学出版社,1988.172.
  • 3国家环保局.水和废水监测分析方法,编委会编水和废水监测分析方法[M].中国环境科学出版社,1989.456.
  • 4国家环保局污染控制司.固体废物申报登记22作指南[Z].,1994.102.

共引文献37

同被引文献56

引证文献7

二级引证文献9

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部