摘要
提出了建筑物火灾危险性评估的一种工程方法。该方法基于建筑火灾的区域模拟理论和人员疏散的最新研究成果,分别计算出火灾中达到危险状态的时间和整个疏散过程所需的时间,通过对比这两个时间,来确定火灾危险性的大小。这种方法概念清晰,简单易行,能在一定程度上对实际建筑物的火灾危险性进行评估,也可用于对火灾的安全工程设计评价和安全咨询。
Based on the experimental results of human evacuation and building fire zone modelling theory, an engineering method for building fire risk analysis has been presented. By calculating theevacuation time and the time to reach the danger condition respectively,and by comparing thesetwo times, the fire risk of the building is determined. This method can make analysis for realbuilding fire to some extent. Because of its simplicity and easy operation, this method can be usedin fire safety design and fire safety consultation.
出处
《中国安全科学学报》
CAS
CSCD
1997年第5期25-28,共4页
China Safety Science Journal