针对两台汽动给水泵同时振动大跳泵的现象,分析跳泵原因,并介绍给水泵最小流量阀的工作机理及运行中对其手动截止阀进行操作时应注意事项。提出对电厂汽水系统阀门操作时要注意其前后压差的变化,避免高压差阀门内发生汽蚀的破坏性。
Two steam-driven pumps to pump striptease at the same time the phenomenon of vibration analysis jump pump reasons,and introduced the minimum flow valve to the pump mechanismand the work of its manual operation of the valve to operate attention should be paid to issues.Proposed power plant steam and water system valves must pay attention to its operation before and after the changes in pressure and avoid high-pressure differential within the cavitation valve destructive.
出处
《河南电力》
2008年第2期55-57,共3页
Henan Electric Power
关键词
给水泵最小流量阀
高压差
节流
汽蚀
振动
minimum flow valve to the pump
high-pressure difference
expenditure
cavitation
vibration