期刊文献+

种植体与精密附着体在上颌单侧游离端缺失修复中的临床应用 被引量:1

Clinical application of dental implant and precision attachment in maxillary unilateral extension denture
下载PDF
导出
摘要 目的:评价XIVE种植体与精密附着体在上颌单侧游离端缺失修复中联合应用的临床疗效。方法:临床选择12例上颌单侧游离牙缺失。全部病例均为双尖牙与磨牙缺失,磨牙区距上颌窦较近,牙槽骨高度<10mm不能直接行种植术。在双尖牙区进行常规种植手术,共植入XIVE种植体24枚,并在种植体上行键槽缓压式(ASC-52)精密附着体修复。结果:随访2年,患者均感觉义齿美观舒适,固位稳定性强,咀嚼功能好。1例种植体周围炎伴附着体上有结石。结论:XIVE种植体与精密附着体在上颌单侧游离端缺失修复的联合应用中,能达到良好的修复效果。 Objective: To evaluate the clinical effects of XIVE implant and precision attachment in maxillary unilateral extension denture. Methods: 12 cases with maxillary unilateral premolars and molars missing were included in this study. The molar areas couldn't accept dental implant because the height of bone was lower than 10mm. 24 XIVE implants were placed in premolar areas and ASC-52 precision attachment dentures were fabricated. Results: All patients were followed up for 2 years. They felt comfortable and esthetical with the dentures. The dentures also showed good retention, stability and masticatary function. Periimplantitis was found in one case. Conclusion: XIVE implant combined with precision attachment could achieve satisfing result in the restoration of maxillary unilateral extension defect.
出处 《口腔颌面修复学杂志》 2008年第1期32-33,共2页 Chinese Journal of Prosthodontics
关键词 种植 XIVE种植体 精密附着体 上颌 游离端 牙缺失 implant XIVE implant precision attachment maxillary flee end tooth loss
  • 相关文献

参考文献5

二级参考文献24

  • 1邸萍,林野,邱立新,李健慧,陈波,王兴.牙种植即刻修复的临床研究[J].中华口腔医学杂志,2004,39(4):265-268. 被引量:34
  • 2贾安琦.附着体的应用及其力学分析[J].国外医学(口腔医学分册),1994,21(5):264-268. 被引量:8
  • 3张德贵.精密附着型可摘局部义齿[J].国外医学(口腔医学分册),1995,22(6):339-343. 被引量:8
  • 4冯海兰,李连生,孟焕新.固定-活动联合修复方法临床应用的初步报告[J].中华口腔医学杂志,1996,31(5):263-266. 被引量:30
  • 5巢永烈.种植义齿学[M].北京:北京医科大学中国协和医科大学联合出版社,1995.5,40-46.
  • 6Branemark PI.Osseointegration and its experimental background.J Prosth Dent,1983,50:399 ~ 410.
  • 7Lorenzoni M,Pertl C,Zhang K,et al.In-patient comparison of immediately loaded and non-loaded implantswithin 6 months.Clin Oral Implants Res,2003,14(3):273 ~ 9.
  • 8Neugebauer J.Modified technique for stage 1 indexing using the XiVE system.Dent Implantol Update,2003,14(10):73 ~ 9.
  • 9Lee CY,Ertel SK.Bone graft augmentation and dental implant treatment in a patient with osteogenesis imperfecta:review of the literature with a case report.Implant Dent,2003,12(4):291 ~ 5.
  • 10McCarthy C,Patel RR,Wragg PF,et al Dental implants and onlay bone grafts in the anterior maxilla:analysis of clinical outcome.Int J Oral Maxillofac Implants,2003,18(2):238~ 41.

共引文献52

同被引文献13

  • 1贾洪宇,施斌.种植体支持对KennedyⅠ类可摘局部义齿应力分布的影响[J].口腔医学研究,2007,23(3):293-296. 被引量:4
  • 2Fueki K, Kimoto K, Ogawa T, et al. Effect of implant-supported or retained dentures on masticatory performance: A systematic review [J]. J Prosthet Dent, 2007, 98 (6) :470 - 477.
  • 3Abu-Saleh T, Marnewick J. Implant-supported crowns for a shortened dental arch: A case report [ J]. J Contemp Dent Praet, 2008, 9(5):114- 121.
  • 4Mengel R, Kreuzer G, Lehmann KM, et al. A telescopic crown concept for the restoration of partially edentulous patients with aggressive generalized periodontitis: A 3-year prospective longitudinal study[J].Int J Period Restor Dent, 2007, 27(3) :231-239.
  • 5Turkyilmaz I. Use of distal implants to support and increase retention of a removable partial denture : A case report [ J ]. J Can Dent Assoc, 2009, 75(9) :655 -658.
  • 6Ohkubo C, Kurihara D, Shimpo H, et al. Effect of implant support on distal extension removable partial dentures: In vitro assessment[J]. J Oral Rehabil, 2007, 34( 1 ) : 52 - 56.
  • 7Kuzmanovic DV, Payne AG, Purton DG. Distal implants to modify the Kennedy classification of a removable partial denture: A clinical report[J]. J Prosthet Dent, 2004, 92( 1 ) : 8 -11.
  • 8Cunha LD, Pellizzer EP, Verri FR, Pereira JA. Evaluation of the influence of location of osseointegrated implants associated with mandibular removable partial dentures [J]. Implant Dent, 2008, 17(3) : 278 -287.
  • 9Matsushita Y, Kitoh M, Mizuta K, et al. Two- dimensional FEM analysis of hydroxyapatite implants: Diameter effects on stress distribution[J]. J Oral Implantol, 1990, 16( 1 ) : 6 -ll.
  • 10Kong L, Gu Z, Li T, et al. Biomechanical optimization of implant diameter and length for immediate loading: A non-linear finite element analysis [J]. Int J Prosthodont, 2009, 22(6) : 607 -615.

引证文献1

二级引证文献5

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史