对3.5 MVA中低碳铬铁电炉炉衬损坏原因进行了分析,并根据电炉自身特点采取了相应的维护措施,延长了炉衬使用寿命,提高了经济效益。
The damaged reasons of furnace lining in 3.5 MVA medium & low carbon ferrochrome furnace have been analysed, and the relevant maintenace measures have also been adopted. The service life of furnace lining can be prolonged and the economic benefits can be raised.