摘要
采用单一活性炭处理法,单一Fenton处理法及活性炭-Fenton试剂联合处理法对头孢噻肟钠模拟废水进行了处理研究。采用这3种方法处理时,废水CODcr去除率分别为52.6%、42.7%和87.6%。可见,采用活性炭-Fenton试剂联合处理头孢噻肟钠模拟废水,可获得较好的处理效果。
The study was conducted on the treatment of the cefotaxime sodium simulated wastewater using the single activated carbon, the single Fenton reagent and the activated carbon-Fenton reagent combination methods in the article. When the three methods were used to treat the wastewater,COD removed rate was 52.6% ,42.7% and 87.6% respectively. It is thus obvious that using the activated carbon-Fenton reagent combination method to treat the cefotaxime sodium simulated wastewater could obtain better treatment result.
出处
《化工科技》
CAS
2008年第2期10-12,共3页
Science & Technology in Chemical Industry
基金
云南省教育厅科学研究基金(重点)资助项目(5Z0679D)
关键词
活性炭
FENTON试剂
头孢噻肟钠
废水
Activated carbon
Fenton reagent
Cefotaxime sodium for Injection
Wastewater