本文从理论上分析了X光机输出射线的特性及影响初始谱分布的因素;提出了X光机辐射能谱调制的附加过滤法。K荧光辐射法、脉冲幅度甄别法和平衡差滤法,并对这些方法的原理及具体应用进行了较详细讨论。
This paper mainly analyses the property of output from X ray units and the factors influencing the primary photon energy spectra, and gives the methods for energy spectra modulation, including additional filtration, K fluorescent, pulse amplitude discrimination and equilibrium difference filter. Their principles and applications were also described. (
出处
《核电子学与探测技术》
EI
CAS
CSCD
北大核心
1997年第5期342-346,共5页
Nuclear Electronics & Detection Technology
基金
清华大学粒子技术与辐射成像国家专业实验室开放基金
关键词
X光机
X射线能谱
能谱调制
X ray units X ray energy spectra Energy spectra modulation)