摘要
根据理论研究和工作实践,以及近年来对已建成防烟工程的调查,从同时开启门数量n的形成机理、影响因素、准确定义、性质、数学模型和物理模型以及取值方法等几个方面,提出了对参数n的理解与分析。
Based on the theoretical study and engineering experiences, and recent investigation on existed smoke control projects, presents the author's understanding and analysis from the perspectives of its forming mechanism, influencing factors, precise definition, mathematical and physical models, and method of detailed value selection
出处
《暖通空调》
北大核心
2008年第2期70-74,共5页
Heating Ventilating & Air Conditioning
关键词
同时开启门数量
防烟
静态
动态
simultaneous opening door number, smoke control, static state, dynamic state