摘要
分析了多级调速泵水系统的技术特性与节能优势,结合上海市公共卫生中心项目空调负荷的分布特点,将多级调速泵灵活地运用到该项目中,在满足特殊使用要求的同时达到了良好的节能效果,为多级调速泵水系统的运用提供了经验。
Analyses the technical characteristics and energy efficiency advantage of the system, and based on the load distribution features of Shanghai Municipal Public Health Center, utilizes the system properly and achieves desirable energy efficiency effects, obtaining valuable experiences for the application of multi-stage variable frequency pump systems.
出处
《暖通空调》
北大核心
2008年第6期3-7,75,共6页
Heating Ventilating & Air Conditioning
关键词
多级调速泵
比例压差控制
富余压头
节能
multi-stage variable frequency pump, proportional pressure-difference control, surplus pressure head, energy efficiency