分析了常规湿式石灰石/石膏法脱硫技术和日本千代田公司的鼓泡塔脱硫技术的工艺差别和脱硫性能,由此对2种工艺的电耗进行了分析研究,对脱硫系统设备选型、节能降耗及提高脱硫效率具有指导意义。
Craft difference and desulphurization performance of conventional wet limestone law desulphurization technology and CT-121 desulphurization technology are analyzed, and research on the electricity consume of that two kinds of crafts is done, which guides the desulphurization equipment selection, energy saving, consume decrease, and improvement of desulphurization efficiency.
出处
《山西电力》
2008年第3期39-41,47,共4页
Shanxi Electric Power
关键词
湿式脱硫
灰石灰/石膏法脱硫
鼓泡塔脱硫
电耗
锅炉
wet desulphurization
limestone/gypsum law desulphurization
CT-121 desulphurization
electricity consumes
boiler