期刊文献+

声场中记录听性稳态反应 被引量:1

The Clinical Application of recording Auditory Steady-state Responses in Sound Field
下载PDF
导出
摘要 目的通过扬声器给声,记录正常听力的成人和婴儿的听性稳态反应结果,探讨其应用价值。方法采用AUDIX测试系统,扬声器给声,分别记录睡眠状态下听力正常的成人(18例,年龄20~22岁,平均21.6岁)和婴儿(11例,月龄5~11个月,平均9.5月)的听性稳态反应阈值。结果正常成人组0.5、1、2、4kHz4个频率的反应阈值分别为73.67±3.12、69.72±4.88、68.74±4.45、71.32±3.35dBSPL;正常婴儿组4个频率的反应阈值分别为77.65±2.36、71.12±3.24、71.80±3.28、72.78±4.12dBSPL。两组各个对应频率的测试结果差异无统计学意义(P〉0.05)。结论成人或者婴儿均可以通过扬声器给声来记录听性稳态反应。 Objective To recorde the auditory steady--state responses of normal hearing peoples and young babies in sound field and to discuss the value. Methods Using loud speaker stimuli, a group of normal hearing adutls and infants were tested. The response thresholds of auditory steady--state responses were recorded. Results For normal adults,the thresholds of ASSR at four frequencies were 73.67±3. 12,69.72±4.88,68. 74±4. 345, 71. 32±3.35 dB SPI. respectively, while for normal infacts, these results were 77.65±2.36,71. 12±3.24,71.80± 3.28,72.7±84.12 dB SPL. The difference of the ASSR thresholds between normal adults and infants has no statislics significance. Oonclusion ASSR could be recorded for normal adults and infants in sound field.
出处 《听力学及言语疾病杂志》 CAS CSCD 2008年第4期299-300,共2页 Journal of Audiology and Speech Pathology
关键词 声场 扬声器 听性稳态反应 Sound field: Loud speaker Auditory steady--state response (ASSR)
  • 相关文献

参考文献6

  • 1Richards FW,Tan LE,Cohen LT, et al. Auditory steady--state evoked potential in newboms[J]. Br J Audiol, 1994,28 : 327.
  • 2Savio G, Cardenas J, Perez Abalo M,et al. The low and high frequency auditory steady state responses mature at different rates[J]. Audiol Neurootol,2001,6 :279.
  • 3Picton TW,Durieux Smith A,Champagne SC,et al. Objective evaluation of aided thresholds using auditory steady-state responses[J], J Am Acad Audiol,1998,9 :315.
  • 4Beauchaine KA,Gorga MP. Applications of the auditory brainstem response to pediatric hearing aid selection[J]. Seminar Hearing, 1988,9 : 61.
  • 5Davidson SA, Watt LG, Goodman CM. Pretiminary studies on the use of an ABR amptitude projection procedure for hearing aid setection[J]. Ear Hear,1990,11:323.
  • 6Picton TW, Dimitrijevic A, Roon PV, et al, Possible roles for the auditory steady-state responses in fitting hearing aids [M]. In: Seewald RC, Gravel JS, Ed, A sound foundation through early amplification. Basel:Phonak, HG,2002.59-69.