期刊文献+

高精度一体化电阻抗断层成像数据采集系统 被引量:2

High precision integrated data collection in electrical impedance tomography
下载PDF
导出
摘要 目的设计一种高精度一体化电阻抗断层成像数据采集系统。方法根据乳腺EIT检测方法的特点,设计了一套16电极高精度一体化实验系统,包括电极、开关阵列、模拟前端、模数转换及数据传送等。系统采用了24位高精度A/D转换和数据采集系统芯片ADuC834,使用了环形电路板,将所有电路集中在该电路板上,以16个压力测试针作为与外部电极的接合点,实现了无长引线的一体化系统。结果使用该系统进行了初步成像实验,取得了较好的成像结果。结论从成像结果看,采用高精度一体化数据采集系统进行EIT成像是可行的,新系统有更高的测量精度。 Objective To develop a high precision integrated data collection system for electrical impedence tomography(EIT). Methods A data collection system was designed and an integrated prototype of breast EIT was developed, which was composed of 16 electrodes,a switch array with multiplexers in a parallel structure, an analogue amplifier,a 24 bit high precision A/D converter and data transmission system. The integrated prototype had no long electrode cables,only consisted 16 elastic needles as the connective points to the outer object,real full data collect chip, and an annular PCB board for integrating all circuits. Results Some preliminary experiments of EIT image were performed and the results were satisfactory. Conclusion The resulted EIT image showed that the new integrated data collection system works effectively and efficiently with high precision.
出处 《生物医学工程与临床》 CAS 2008年第4期334-337,共4页 Biomedical Engineering and Clinical Medicine
基金 国家自然科学基金重点项目(50337020) 天津市自然科学基金项目(06YFJMJC10900)
关键词 电阻抗断层成像 高精度采集 一体化系统 electrical impedance tomography (EIT) high precision data collection integrated system
  • 相关文献

参考文献11

  • 1Isaacson D. Distinguishability of conductivities by electric current computed tomography[J]. IEEE Trans Med Imaging, 1986, MI-5(2) :91-95.
  • 2Murphy D, Rolfe P. Aspects of instrumentation design for impedance imaging [J]. Clin Phys Physiol Meas, 1988,9 Suppl A:5-14.
  • 3Cherepenin V,Karpov A,Korjenevsky A,et al. Preliminary static EIT images of the thorax in health and Disease [J]. Physiol Meas,2002,23( 1 ) :33-41.
  • 4Rigaud B, Morucci JP. Bioelectrical impedance techniques in medicine.Part Ⅲ :Impedance imaging. Third section:medical applications[J]. Crit Rev Biomed Eng, 1996,24 (4-6) :467- 597.
  • 5Wang Huaxiang, Wang Chao, Yin Wuliang. Optimum design of the structure of the electrode for a medical EIT system [J]. Meas Sci Technol, 2001,12 (8) : 1 020-1023.
  • 6董秀珍.生物电阻抗技术研究进展[J].中国医学物理学杂志,2004,21(6):311-317. 被引量:68
  • 7Jie Zhang, Patterson PP. EIT images of ventilation:what contributes to the resistivity changes[J]? Physiol Meas, 2005,26 (2) :S81-92.
  • 8Cook RD, Saulnier GJ, Gisser DG, et al. ACT3 : A high-speed, high precision electrical impedance monograph[J]. IEEE Trans Biomed Eng, 1994,41:713-722.
  • 9Smith RW,Freeston IL,Brown BH. A real-time electrical impedance tomography system for clinical use-design and preliminary results[J]. IEEE Trans Biomed Eng, 1995,42(2) : 133-140.
  • 10Edic PM,Saulnier GJ,Newell JC,et al. A real time electrical impedance tomography[J]. IEEE Trans Biomed Eng, 1995,42 (9) :849-859.

二级参考文献29

  • 1尤富生,董秀珍,史学涛,付峰,刘锐岗,秦明新,汤孟兴,李江.电阻抗断层成像硬件系统的初步研究[J].中国体视学与图像分析,2003,8(2):114-118. 被引量:8
  • 2A T Tidswell,A Gibson, R H Bayford, et al. Electricalimpedance tomography of human brain activity with a two-dimensional ring of scalpelectrodes[J]. Physiol. Means., 2001,22:167-175.
  • 3Sutcliffe JF.A review of in vivo experimental methods to determ ine the composition of the human body[J]. Phys. Med.Biol., 1996,41:791-833.
  • 4Dick C, Gerald F, Andrei V., et al. Adipose tissue compartments and insulin resistance in overweight-obese Caucasian men [J].Diabetes Research and Clinical Practice, 2004,63:77-85.
  • 5Hermann Scharfetter, Stephan Rauchenzauner, Robert Merwa, Planar gradiometer for magnetic induction tomography (MIT)[J]. Theoretical and experimental sensitivity maps for a low-contrast phantom. Physiol. Meas., 2004,25:325-333.
  • 6Sramek BB. Stroke volume equation with a linear base impedance model and its accuracy, as compared to thermodilution and magnetic flowmeter techniques in human and animals [J].Proceedings of 6th ICEBI, Kroatia, 1983.33-39.
  • 7Zhang Z X, Xu Y J, Zeng G B. Noninvasive quant it at ivediagno sis of pulmonary artery hypertension with impedance rheopneumogram in patients with chronic obstructive pulmonary disease[J]. J Tongji Med Univ., 1993,13:167-172.
  • 8Hyun Soo Khang, Byung Il Lee, Suk Hoon Oh, et al. J-Substitution Algorithm in Magnetic Resonance Electrical Impedance Tomography (MREIT)[J]. Phantom Experiments for Static Resistivity Images. IEEE Transactions on Medical Imaging, 2002,21(6):695-702.
  • 9Bache RJ, Harley A, Greenfield JC. Evaluation of thoracic impedance plethysmography as an indicator of stroke volume in man[J]. Am.J. Med. Sci., 1969,258(8):100-13.
  • 10TJC Faes, HA Meij, JC Munck, et al. The electrical resistivity of human tissues (100 Hz-10 MHz): a meta-analysis of review studies[J]. Physiol. Meas., 1999,20(1):R1-10.

共引文献67

同被引文献14

引证文献2

二级引证文献8

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部