摘要
对石洞口二厂600MW超临界压力锅炉的了辐射区进行了水动力特性及壁温工况的计算和分析,以探明其变压运行性能。
This paper takes 600MW supercritical pressure boller of Shidongkou stationNo .2 as its researching object. The calculation and analysis were completed on the hydro-dynamics and wall-temperature condition of low radiation zoae. Tbe work can exploreproperty of variable pressure operation in the boiler.
出处
《锅炉技术》
北大核心
1997年第9期4-7,15,共5页
Boiler Technology
关键词
变压运行
下辐射区
壁温
工况
超临界
压力锅炉
Variable pressure operation Low radiation zone Phase change point Wall-temperature condition