摘要
介绍了火力发电厂管道应力计算和应力分析及支吊架检查调整原理和方法,给出了管道支吊架冷、热态应力计算的结果,并提出了失效支、吊架调整的具体措施。
This paper introduces the stress calculation and analysis of the pipeline in thermal power plant, the testing and adjusting principle and method of support and hanger ,presented the stress calculation result of support and hanger at the cold and hot state, also proposed the concrete measures for adjusting failure supports and hangers.
出处
《华北电力技术》
CAS
2008年第7期9-11,共3页
North China Electric Power
关键词
火力发电厂
管道
支吊架
应力分析
调整
thermal power plant
pipeline
support and hanger
stress analysis
adjustment