介绍和分析了城镇传统二次增压供水系统中耗能的各个环节,并根据具体情况提出了管网余压节能、泵站内部节能及管网压力优化节能3种解决方案,以期为供水企业在增压泵站供水系统改扩建方面提供参考.
This paper introduces and analyses the aspects of conventional second pressured water supply system energy-saving and brings out measures accordingly. These are included:pipe network residual pressure energysaving,pump station energy-saving and pipe network pressure optimization,which are expected to provide references for water-supply enterprise on rebuilding and building a continuation to conventional second pressured pump station.
出处
《河南科学》
2008年第7期822-824,共3页
Henan Science
基金
国家科技支撑计划项目"小城镇饮用水输送系统水质保障技术"(2006BAJ08B03)
关键词
管网余压
泵站
压力优化
节能降耗
pipe network residual pressure
pump station
pressure optimization
energy-saving