期刊文献+

静电旋风除尘技术的现场试验 被引量:6

The Pilot Test of Electrostatics cyclone Precipitation Technology
下载PDF
导出
摘要 对静电旋风除尘技术的机理进行探讨.现场试验表明,此技术用于电厂旋风水膜除尘器的改造,可将平均除尘效率由92.55%提高到98.4%,且对不同浓度的烟尘除尘效率比较稳定.在处理烟气量为10600Nm3/h时,阻力为800-920Pa,高压电源的单位能耗为0.2W·h/(m3·h). he mechanism of electrostatics cyclone precipitation technology has been researched in this paper.The pilot demonstration showed that this technology,using to improve the wet cyclone precipitator of power station,can heighten the precipitation efficiency from 92 55% to 98.4%.The precipitation efficiency for different concentration of flue gas is quite stable.When the gas flow is 10600 Nm 3/h,the resistance is 800-920 Pa and the consumption per unit flow of high voltage power supply is 0.2 W·h/(m 3·h).
出处 《环境科学》 EI CAS CSSCI CSCD 北大核心 1997年第6期39-41,共3页 Environmental Science
基金 国家"九五"科技攻关项目
关键词 静电旋风除尘 电厂 除尘 electrostatics cyclone precipitation technology,wet cyclone precipitation, high voltage power.