期刊文献+

离子迁移谱系统的优化设计及其在甲苯检测中的应用 被引量:1

Optimization of ion mobility spectrum system and application in detection of toluene
下载PDF
导出
摘要 以对痕量甲苯的检测为例,研究了以激光作为电离源的离子迁移谱对痕量物质进行检测的方法.对离子迁移谱系统进行了优化,得到了最佳的迁移管长度和管内电场强度;同时研究了迁移信号和样品浓度的关系.结果表明,该方法行之有效,并能取得极高的灵敏度. Trace amount, a method for detect trace amount substance, such as toluene, using an ion mobility spectrometer equipped with a laser ionization source, is researched. The ion mobility spectrum system has been optimized. The length of the. mobility tube and the electric field intensity have been adjusted to optimum, and the relationship between the drift signal and the sample concentration has been studied. The result shows that the method is highly sensitive and effective.
出处 《物理实验》 2008年第7期12-15,共4页 Physics Experimentation
基金 曲阜师范大学博士科研启动基金资助
关键词 离子迁移谱 甲苯 优化设计 电场强度 样品浓度 ion mobility spectrum toluene optimized design electric field intensity sample concentration
  • 相关文献

参考文献15

  • 1Lawrence A H. Characterization of benzodiazepine drugs by ion mobility spectrometry [J]. Anal. Chem. , 1989,61(4) :343-349.
  • 2Eiceman G A, Karpas Z. Ion mobility spectrometry [M]. Boca Raton.. CRC Press, 1994:1-228.
  • 3Karasek F W, Keller R A. GC-PC interface and its performance in the detection of musk ambrette [J]. Chromatogr. Sci. , 1972,10:626.
  • 4Sielemann S, Baumbach J I, Pilzecker P, et al. Detection of trans-1, 2-dichloroethene, trichloroethene and tetrachloroethene using multi-capillary columns coupled to ion mobility spectrometers with UV-ionisation sources [J]. Int. J. Ion Mobility Spectrom. , 1999,2:15-21.
  • 5Sielemann S, Baumbach J I, Schmidt H, et al. Detection of alcohols using UV-ion mobility spectrometers [J]. Anal. Chim. Acta, 2001,431:293-301.
  • 6Karpas Z. Ion mobility spectrometry of aliphatic and aromatic amines [J]. Anal. Chem. , 1989,61: 684-689.
  • 7Siems W F, Wu C, Tarver E E, et al. Measuring the resolving power of ion mobility spectrometers [J]. Anal. Chem., 1994,66:4 195-4 201.
  • 8Lawrence A H. Characterization of benzodiazepine drugs by ion mobility spectrometry [J]. Anal. Chem. , 1989,61:343-349.
  • 9Ewing R G, Atkinson D A, Eiceman G A, et al. A critical review of ion mobility spectrometry for the detection of explosives and explosive related compounds [J]. Talanta, 2001,54(3) :515-529.
  • 10Bell S E, Ewing R G, Eiceman G A, et al. Atmospheric pressure chemicalionization of alkanes, alkenes, and cycloalkanes [J]. J. Am. Soc. Mass Spectrom. , 1994,5(3):177-185.