期刊文献+

拉曼喷泉原子钟 被引量:1

Raman Atomic Fountain Clock
原文传递
导出
摘要 利用拉曼光场代替喷泉原子钟的微波腔实现拉曼喷泉原子钟。将分离拉曼光场技术与冷原子喷泉技术相结合,避免了在真空腔内放置微波腔,简化了真空系统,同时还保持了很高的准确度。采用半经典理论研究了冷原子喷泉与拉曼光场的相互作用过程,得到了冉赛(Ramsey)条纹。比较了拉曼喷泉原子钟与热铯束拉曼原子钟,前者有更小的体积和功耗,其精度可能达到或超过商用小铯钟。还比较了拉曼喷泉原子钟与微波喷泉原子钟的差别,分析了光子反冲的影响,提出利用同向传播和相向传播的两台拉曼原子钟测量精细结构常数。 An atomic fountain clock based on Raman laser field instead of microwave cavity is proposed. This scheme combines the separate Raman fields technology and the cold atomic fountain technology, cancels the microwave fountain clock in the vacuum cavity and meanwhile keeps a high accuracy. The interaction process of the cold atomic fountain and the Raman laser field is studied with the semiclassical theory and the Ramsey fringes are acquired. The Raman fountain clock is compared with the atomic beam clock of hot cesium atoms, and it is found that the accuracy of Raman fountain clock higher and its capacity and power consumption are much smaller. Compared with the microwave fountain clock, the Raman fountain clock must consider the influence of photon recoil. With the photon recoil, it is proposed to measure the fine structure constant by using two Raman fountain clocks.
出处 《光学学报》 EI CAS CSCD 北大核心 2008年第7期1390-1394,共5页 Acta Optica Sinica
基金 上海市浦江人才计划资助课题
关键词 量子光学 拉曼光场 原子干涉 喷泉原子钟 quantum optics Raman laser field atomic interference atomic fountain clock
  • 相关文献

参考文献16

  • 1A. Clairon, C. Salomon, S. Guellati. Ramsey resonance m a Zacharias fountain[J]. Europhys. Lett., 1991, 16(2): 165-170
  • 2Paul D. Lett, Richard N. watts, Christoph I. Westbrooket al.. Observation of atoms laser cooled below the Doppler limit[J]. Phys. Rev. Lett. , 1988, 61(2): 169-172
  • 3A. Clarion, P. Laurent, G. Stantarelliet al.. A cesium fountain frequency standard: preliminary result[J].IEEE Trans. on Inst. And Meas. , 1995, 44(2): 128-131
  • 4Andreas Bauch, Roland Schroder. Experimental verification of the shift of the cesium hyperfine transition frequency due to blackbody radiation[J].Phys. Rev. Lett., 1997, 78(4): 622- 625
  • 5Christophs Salomon, Christian Veillet. ACES: atomic clock ensemble in space[J]. ESA Space Station Utilization Symposium, Darmstadt 1996, SP-385 295-297
  • 6Kurt Gibble. Laser-cooled microgravity clocks[J]. IEEE Int. Freq. Control Symp. , 1998, 52:41-45
  • 7H. G. Robinson, S. R. Jefferts, D. B. Sullivan. Design studies for a laser-cooled space clock [J]. IEEE Int. Freq. Control Symp. , 1998, 52:37-40
  • 8李天初,李明寿,林平卫,等.2005年NIM4铯喷泉钟的改进和最新评估[C]//2005年全国时间频率学术交流会论文集.西安:2005年全国时间频率学术交流会组织委员会,2005:1-5.
  • 9魏荣,李唐,边风刚等.上海光机所冷原子钟研究的进展[C].2005年全国时间频率学术交流会论文集,2005
  • 10边风刚.小喷泉^87Rb原子钟的设计与空间冷原子钟的研究[D].上海:上海光学精密机械研究所,2006

共引文献1

同被引文献45

  • 1M Boshier, D Berkeland, T R Govindan, et al.. Quantum Technology and Its Applications[R]. Los Alamos: Los Alamos National Laboratory, 2010. 8-10.
  • 2A Clairon, C Salomon, S Guellati, et al.. Ramsey resonance in a Zacharias fountain[J]. Europhys Lett, 1991, 16 (2): 165-170.
  • 3M Kasevich, E Riis, S Chu, et al.. RF spectroscopy in an atomic fountain[J]. Phys Rev Lett, 1989, 63(6) : 612-615.
  • 4A Clairon, P Laurent, G Santarelli, et al.. A cesium fountain frequency standard: preliminary results[J]. IEEE Trans Instrumentation and Measurement, 1995, 44(2) : 128- 131.
  • 5S A Diddams, J C Bergquist, S R Jefferts, et al.. Standards of time and frequency at the outset of 21st century[J]. Science, 2004, 306(5700): 1318-1324.
  • 6Ch Salomon, N Dimarcq, M Abgrall, et al.. Cold atoms in space and atomic clocks: ACES[J]. Comptes Rendus De L Academic Des Sciences Serie Iv Physique Astrophysique, 2001, 2(9): 1313-1330.
  • 7T P Heavner, L W Hollberg, S R Jefferts, et al.. Characterization of a cold cesium source for PARCS: primary atomic reference clock in space[J]. IEEE Trans Instrumentation and Measurement, 2001, 50(2): 500-502.
  • 8H Schnatz, B Lipphardt, C Degenhardt, et al.. Optical frequency measurements using fs-comb generators[J]. IEEE Trans Instrumentation and Measurement, 2005, 54(2): 750-753.
  • 9L Hollberg, C W Oates, G Wilpers, et al.. Optical frequency/wavelength references[J]. J Phys B, 2005, 38 (9): S469-S495.
  • 10H Katori. Spectroscopy of strontium atoms in the Lamb-Dicke confinement[C]// Proceedings of the 6th Symposium on Frequency Standards and Metrology, 2002. 323-330.

引证文献1

二级引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部