摘要 目的:比较不同粒度金刚砂车针预备的牙体对烤瓷修复体基底冠适合性的影响。方法:采用4种不同粒度车针对预备牙面进行打磨,根据最终使用车针型号的不同将离体牙试件分为4组,分别制取印模并制作基底冠。采用玻璃离子水门汀将基底冠粘固在牙体上,评价其微渗漏情况和适合性。结果:预备体表面采用车针打磨至不同水平的各组牙试件,经玻璃离子粘固后的微渗漏等级之间存在显著性差异(P<0.05),各组基底冠与牙体之间的粘固剂厚度也存在显著性差异(P<0.01)。结论:随车针粒度的减小,牙预备体与镍铬合金基底冠之间的适合性逐渐提高。 Objectlve:The aim of this study was to evaluate the adaptation between Ni-Cr based crown and dentin prepared and polished by diamond burs with different grits. Method: According to the type of the latest diamond burs used for the finishing of tooth preparation,all the prepared teeth were divided into 4 groups. The impressions were made and based crowns were fabricated with Ni-Cr alloy. Glass ionomer cement was used for cementing the crowns. The bonded specimens were evaluated for microleakage and adaptation. Result: There were significant difference on microleakage (P〈0.05) and film thickness of cement (P〈0.01) between dentin and Ni-Cr based crowns in all the tested groups. Conclusion: As the grit size of diamond bur for preparation decreases, the adaptation between dentin and Ni-Cr based crown increased.
出处 《临床口腔医学杂志》 2008年第6期361-363,共3页 Journal of Clinical Stomatology
关键词 粗糙度 牙本质 玻璃离子水门汀 微渗漏 适合性 surface roughness dentin glass ionomer cement microleakage adaptation
  • 相关文献

参考文献8

  • 1马轩祥.口腔修复学[M].第5版.北京:人民卫生出版社,2004:1.
  • 2邬烈,骆小平.固定修复体适合性的研究方法[J].口腔颌面修复学杂志,2007,8(1):68-70. 被引量:18
  • 3Irie M,Suzuki K,Watts DC. Marginal and flexural integrity of three classes of luting cement, with early finishing and water storage [J]. Dental Materials, 2004,20 (1) : 3-11.
  • 4Tjan HL,Sarkissian R. Effect of prepatation finish on retention and fit of complete crowns[J]. J Prosthet Dent, 1986, 56(3):283-288.
  • 5吉宁,王少安.瓷全冠边缘适合性的影响因素[J].国外医学(口腔医学分册),2005,32(2):148-150. 被引量:12
  • 6郑庄,唐亮.粘接材料与口腔固定修复的微渗漏(讲座)[J].暨南大学学报(自然科学与医学版),2003,24(4):111-114. 被引量:13
  • 7American Dental Association. ANSI/ADA Specification No.8 for zinc phosphate cement In: Guide to dental materials and devices [M]. 5th ed.Chicago: American Dental Association, 1970-1.
  • 8Mclean JW, Von Fraunhofer JA. The estimation of cement film thickness by an in vivo technique[j]. Br Dent J, 1971,131 (3) : 111- 127.

二级参考文献50

  • 1梁钦业,赵玮,赵云凤,李哲.镍铬钛合金铸造全冠适合性的研究[J].四川大学学报(自然科学版),2001,38(S1):126-129. 被引量:3
  • 2WHITE S N, KIPNIS V. Effect of adhesive luting agents on the marginal seating of cast restorations[J]. J Prosthet Dent, 1993, 69(1):28-31.
  • 3FLEMING G J, NARAYAN O. The effect of cement type and mixing on the bi- axial fracture strength of cemented aluminous core porcelain discs[J]. Dent Mater, 2003, 19(1) :69 - 76.
  • 4CELIK C, GEMALMAZ D. Comparison of marginal integrity of ceramic and composite veneer restorations luted with two different resin agents:an in vitro study[J]. Int J Prosthodont, 2002, 15(1):59-64.
  • 5YIM N H, RUEGGEBERG F A, CAUGHMAN W F, et al. Effect of dentin desensitizers and cementing agents on retention of full crowns using standardized crown preparations[J]. J Prosthet Dent, 2000, 83(4):459-465.
  • 6MILLER B H, NAKAJIMA H, POWERS J M, et al. Bond strength between cements and metals used for endodontic posts[J]. Dent Mater, 1998,14(5) :312-320.
  • 7SQUIER R S, AGAR J R, DUNCAN J P, et al. Retentiveness of dental cements used with metallic implant components[J]. Int J Oral Maxillofac Implants, 2001, 16(6):793-798.
  • 8PURTON D G, LOVE R M, CHANDLER N P. Rigidity and retention of ceramic root cannal posts[J]. Oper Dent,2000, 25(3) :223 - 227.
  • 9O'KEEVE K L, MILLER B H, POWERS J M. In vitro tensile bond strength of adhesive cements to new post materials[J]. Int J Prosthodont, 2000, 13(1):47-51.
  • 10Wolfart S, Wegner SM, Al-Halabi A, et al. Int J Prosthodont, 2003, 16(6) :587-592.

共引文献51

同被引文献40

  • 1李刚.牙钻在牙科史上的变革和发展[J].中国实用口腔科杂志,2009,2(2):124-124. 被引量:3
  • 2杨峰.两种玻璃离子水门汀主要性能的试验研究[J].河南职工医学院学报,2005,17(3):141-143. 被引量:7
  • 3邬烈,骆小平.固定修复体适合性的研究方法[J].口腔颌面修复学杂志,2007,8(1):68-70. 被引量:18
  • 4Wahl C, Franca FM, Brito RB Jr, et al. Assessment of the tensile strength of hexagonal abutments using different cementing agents. Braz Oral Res. 2008;22(4):299-304.
  • 5Michalakis KX, Pissiotis AL, Hirayama H. Cement failure loads of 4 provisional luting agents used for the cementation of implant-supported fixed partial dentures. Int J Oral Maxillofac Implants. 2000;15(4):545-549.
  • 6Macari S, Goncalyes M, Nonaka T, et al. Scanning electron microscopy evaluation of the interface of three adhesive systems. Braz Dent J. 2002;13(1):33-38.
  • 7Wilson AD, Prosser H J, Powis DM. Mechanism of adhesion of polyelectrolyte cements to hydroxyapatite. J Dent Res. 1983;62(5): 590-592.
  • 8Glasspoole EA, Erickson RL, DaVidson CL. Effect of surface treatments on the bond strength of glass ionomers to enamel. Dent Mater. 2002;18(6):454-462.
  • 9Song XF, Yin L. The quantitative effect of diamond grit size on the subsurface damage induced in dental adjustment of porce- lain surfaces. P I Mech Eng H, 2010, 224(10): 1185-1194.
  • 10Ayad MF, Johnston WM, Rosenstiel SF. Influence of dental ro- tary instruments on the roughness and wettability of human dentin surfaces. J Prosthet Dent, 2009, 102(2): 81-88.

引证文献4

二级引证文献15

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部