期刊文献+

下腰椎椎弓根螺钉误入椎管损伤神经根的临床分析 被引量:7

下载PDF
导出
出处 《脊柱外科杂志》 2008年第3期178-180,共3页 Journal of Spinal Surgery
  • 相关文献

参考文献10

  • 1[1]Lonstein JE,Denis F,Perm JH.et al.Complications associated with pedicle screws[J].J Bone Joint Surg Am,1999,81(11):1519-1528.
  • 2[2]Masferrer B,Gomnez CH,Karahalios DG,et al.Rfficacy of pedi-cle screw frxation in the treatment of spinal instability and failed back surgery:a 5-year review[J].J Neurosurg,1998,89(3):371 -377.
  • 3[3]Fsses SI,Sachs BL,Dreyzin V.Complications associated with the technique of pedicle screw fixation.A selected surrey of ABS members[J].Spine,1993,18(15):2231-2238.
  • 4崔新刚,张佐伦,王道军,刘峰,秦德安.腰椎三种椎弓根定位方法的对比解剖学研究及意义[J].中国脊柱脊髓杂志,2005,15(7):433-435. 被引量:12
  • 5[6]Hsu CJ,Chou WY,Chang WN,et al.Clinical follow up after in-stmmentation-angmented lonbar spinal surgery in pail 是 "ents with unsatisfactory outcomes[J].J Neurosurg Spine,2006,5 (4):281 -286.
  • 6[7]Heyde CE,Bohm H,el-Saghir H,et al.First experience of intrao-perative nerve root monitoring with the INS-1-device on the lumbo-sacral spine[J].Z Orthop Ihre Grenzgeb,2003,141 (1):79-85.
  • 7[8]Jon IM,Hsu CC,Chem TC,et al.Spinal somatosensory evoked potential evaluation of acute nerve-root injury associated with ped-icle-screw placement procedures:an experimental study[J].J Orthop Res,2003,21 (2):365 -372.
  • 8[9]Papadopoulos EC,Girardi FP,Sama A,et al.Accuracy of sin-gle-time,multilevel registration in image-guided spinal surgery[J].Spine J,2005,5(3):263 -267.
  • 9[10]Laine T,Lund T,Ylikoski M,et al.Accuracy of pedicle screw insertion with and without computer assistance:a randomised controlled clinical study in 100 consecutive patients[J].Eur Spine J,2000,9(3):235 -240.
  • 10[11]Toleikis JR,Skelly JP,Carlvin AO,et al.The usefulness of e-lectrical stimulation for assessing pedicle screw placemonts[J].J Spinal Disord,2000,13(4):283 -289.

二级参考文献7

  • 1崔新刚,张佐伦,刘建营,刘峰,秦德安.棘突定位法在胸腰椎椎弓根螺钉内固定中的应用[J].中国脊柱脊髓杂志,2004,14(7):429-431. 被引量:8
  • 2陈家强,周立兵,余明华,王汉琴.胸腰椎椎弓根的解剖学测量及其临床意义[J].解剖学研究,2004,26(1):63-65. 被引量:36
  • 3Ebraheim NA,Rollins JR,Xu R,et al. Projection of the lumbar pedicle and its morphometric analysis [J].Spine, 1996,21 (11):1296-1300.
  • 4Brumagne S, Lysene R,Swinnen S,et al. Effect of paraspinal muscle vibration on position sense of the lumbosacral spine[J].Spine, 1999,24(13): 1328-1331.
  • 5Thomsen K, Christensen FB,Eiskjaer SP,et al. The effect of pedicle screw instrumentation on functional outcome and fusion rates in posterolateral lumbar spinal fusion:a prospective,randomized clinical study[J].Spine, 1997,15:22(24) :2813.
  • 6Muller A,Gall C,Marz U,et al. A keyhole approach for endoscopically assisted pedicle screw fixation in lumbar spine instability[J].Neurosurg, 2000,47 (1):85-95.
  • 7杜心如,赵玲秀,张一模,叶启彬.腰椎人字嵴顶点椎弓根螺钉进钉方法的解剖学研究[J].中国临床解剖学杂志,2002,20(2):86-88. 被引量:115

共引文献11

同被引文献109

引证文献7

二级引证文献29

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部