期刊文献+

联机—速差动力学分析法同时测定铁钛的研究 被引量:1

On Computerized Kinetic Analytical Method for the Simultaneous Determination of Trace amount of Iron(Ⅲ) and Titanium (Ⅳ)
下载PDF
导出
摘要 利用5-溴水杨基荧光酮,CTMAB与Fe(Ⅲ),Ti(Ⅳ)形成的三元配合物显色体系,采用联机检测技术,结合流动注射方法,对双组分金属离子进行了速差动力学同时测定的研究,并且测定了电铸液中Fe(Ⅲ)的含量。结果表明,该方法不仅排除了Ti(Ⅳ)的干扰,而且测定了Ti(Ⅳ)的含量。方法的回收率在96%~106%之间。样品处理简便,电铸液中其它组分基本不干扰测定。 The computerized kinetic analytical method has been developed for the simultaneous determination of trace iron (Ⅲ) and titanium (Ⅳ) in electrocasting solution ,by detection of the coloration system of 5 bromo salicylfluorone with CTMAB and Fe3+ or Ti(Ⅳ). The method can detect Fe3+,Ti (Ⅳ) without the interference of Ti (Ⅳ). The recovery is 96 ̄106%,and the sample processing procedure is simple . Other components in the electrocasting solution don't interfere the determination.
出处 《无锡轻工大学学报(食品与生物技术)》 CSCD 1997年第4期56-60,共5页 Journal of Wuxi University of Light Industry
关键词 流动注射分析 速差动力学 CTMAB 电铸液 kinetic analysis electrocasting solution iron titanium 5 bromosalicylfluorone
  • 相关文献

参考文献3

二级参考文献34

共引文献22

同被引文献68

引证文献1

二级引证文献4

相关作者