摘要 [目的]探讨医学实验室对ELISA的测量不确定度的评定方法。[方法]用ELISA测定3份血清中不同浓度的癌胚抗原并作批内重复,根椐直线回归方程建立数学模型,分析不确定度来源并计算各分量标准不确定度、合成标准不确定度、扩展不确定度。[结果]ELISA测定3份血清中癌胚抗原的测量不确定度分别为±1.58ng/ml、±5.90ng/ml、±9.75ng/ml(包含因子k=2.101)。[结论]包含有测量不确定度的结果更能反应测量的真实水平,但医学实验不确定度的评定方法还应深入探索。 [Objective] To study on evaluation of the uncertainty in measurement of ELISA in medical laboratory.Methods The CEA of 3 samples of serum were detected by ELISA and in-repeatabition,setting up a mathematical model in accordance with linear regression equation.Analyzed the source of the uncertainty and calculated the standard uncertainty of each portion、 the combined standard uncertainty and the expanded uncertainty.Results The uncertainty in measurement of ELISA detecting CEA of 3 samples were as follows:±1.58ng/ml,±5.90ng/ml,±9.75 ng/ml(the coverage factor K= 2.101).Conclusion The result of containing the uncertainty can better reflect the real level of test,however,there’s still a long way to study the evaluation of the uncertainty in measurement of medical laboratory.
作者 李多孚 李欣
出处 《现代预防医学》 CAS 北大核心 2008年第15期2947-2949,共3页 Modern Preventive Medicine
关键词 医学实验室 ELISA 癌胚抗原 测量不确定度 Medical laboratory ELISA,CEA Uncertainty in measurement
  • 相关文献

参考文献4

  • 1曹桂荣,申子瑜.医院管理学临床实验室管理分册[M].北京:人民卫生出版.2003.127-141.
  • 2JJF1059-1999.测量不确定度评定与表示[S].[S].,..
  • 3张霞,张荣新,周永浩.测量不确定度及其应用[J].环境与健康杂志,2003,20(1):59-61. 被引量:5
  • 4Ricos C, Alvarez V, Cava F, et al. Current databases on biological variation: pros, cons and progress [J]. Scand J Clin Lab Invest, 1999, 59: 491-500.

二级参考文献1

共引文献782

同被引文献12

引证文献3

二级引证文献6

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部