摘要
论述了在除尘器内部或外部设盘管加热,在除尘管道上设伴热管或夹套管加热的间接加热法防止除尘系统结露的设计计算方法.
In this paper,a calculating method of design is given to protect dust-removal system from dewing with indirect heating.The imdirect heating methods are designed by the coil inside or outside the dust-remover and being heated with accompanying heating-pipe or casing pipe outside the dust line.
出处
《青岛建筑工程学院学报》
1997年第3期35-41,共7页
Journal of Qingdao Institute of Architecture and Engineering
关键词
除尘器
除尘系统
结露
间接加热法
设计
the internal heating method,the external heating method,accompanying heating-pipe