螺旋CT扫描下颈椎对下颈椎椎弓根螺钉的置入作用 被引量:1

Transpedicular screw placement evaluated by axial computed tomography of the cervical pedicle
下载PDF
导出
摘要 目的通过测量颈椎椎弓根尺寸和进钉点进钉角度为置入椎钉提供依据。方法CT测量30例患者颈3-7,CT扫描测量颈椎根以下尺寸,椎根内径、外径、内侧皮质厚度、椎弓根轴长度和椎弓根长轴与中线的夹角。结果颈椎椎弓根平均内径为L3-3.3mm,颈椎椎弓根平均外径为4.0-7.0mm,最小的椎弓根在女性颈3椎体,最小的椎弓根外径为3.2 mm,最大椎弓根宽为C7,男性为11.3 mm,女性为7.4 mm。平均内壁皮质骨厚度为1.5-2.0 mm,平均椎弓根轴长度29.3to-33.7mm和平均椎弓根长轴与中线的夹角39.8度to 49.0度。结论颈椎椎弓根螺钉的置入应行CT测量,螺钉角度接近50度,进钉角度尽可能在侧块的外侧。 Objectives To provide a safe transpedicular screw trajectory by measuring the dimensions of the cervical pedicle and evaluating the entrance points and the insertion angles of transpodicular screws. Methods The dimensions of the podicles (C3-C27) were determined in 30 patients with cervical spinal lesions from CT images. CT images in which each podicle appeared largest were selected and the following dimensions determined:pedicle inner and outer widths,medial cortical thickness,pedicle axis length and the podicle transverse angle. Results The mean inner pedicle width ranged from 1.3 to 3.3mm,the mean outer pedicl width ranged from 4.0 to 7.0mm.The smallest pedicle Width was found at C3 among the female subjects for both inner and outer pedicles,The smallest outer podich width was 3.2mm,the largtest pedicle width was at C7 in both males (11.1mm) and females(7.4mm).The mean medial cortical thickness ranged from 1.5 to 2.0mm. The pedicle axis length ranged from 29.3 to 33.7mm.The mean pedicle transverse angle ranged from 39.8 to 49.0 degree. Conclusions Axial CT measurements should facilitate transpodicular screw fixation in the cervical spine. We believe that the screw insertion angle should be close to 50 degrees,which is the mean podicle transverse angle from C3-C6.The entrypoint of the podicle screw should be located as laterally as possible in the posterior surface of the lateral mass.
出处 《海南医学》 CAS 2008年第8期30-31,共2页 Hainan Medical Journal
关键词 颈椎 内固定 三维CT Cervical spine Internal fixation Three-dimension CT
  • 相关文献

参考文献12

  • 1Kotani Y, McNulty PS, Abumi K, et al. Biomechamcal analysis of cervical stabilization systems:an assessnlet of wanspedieular screw frxation in the ccervical apme.Spme,1994,19:2529-39.
  • 2Jones EL, Heller JG, Sileox DH, et al. Cervical pedicle screws versus lateral mass screws:anatomic feasibility and biomechanical comparison,spine, 1997,22:977-82.
  • 3Abumi K, Shono Y, Taneichi H,et al. Correction of cervical kyphosis using pedicle scrsw frxation systems.Spine, 1999,24:2389-96.
  • 4Abumi K, Kanoda K, Shono Y, et al. One-stage posterior decompression and reconstruction of the cervical spine by using pedicle screw fixation systems. J Neurosurg,1999,90:19-26.
  • 5Abumi K, Shono Y, Ito M, et al. Complications of pedicle screw frxation in recomtmctive surgery of the cearvical spine. Spine,2002,25:962-9.
  • 6Abumi K,Ito. Taneichi H, et al. Transpedicular screw fmation for traumatic lesions of the middle and lower cervical spree:description of the techniques and preliminary report. J Spinal Disord, 1994,7:19-28.
  • 7Kotani Y,Abumi K,Ito M, et al. Improved accuracy d computer-assisted cervical pedicle screw insertion. JNeurosurg, 2003,199:257 -63.
  • 8Karaikovic EE, Daubs MD, Mad. sen RW, et al. Morphologic characteristics of human cervical peclicles. Spine, 1997,22:493-500.
  • 9Panjabi MM, Shin EK Chen NC, et al. Internal morphology of human cervical pedicles. Spine 2000,25:1197-205.
  • 10Shin EK, Panjabi MM.Chen NC, et al. The anatomic variability of human cervical peclicles:eonsiderahom for trsnspedicular,screw fixation in the middle and lower cervical spree. Eur Spree J, 2000,9:61-6.

二级参考文献17

  • 1高雨仁,杨桂姣,阎八一,马迅,马景昆,张建中.颈椎后路关节突-椎弓根联合内固定的解剖学基础[J].解剖学杂志,1994,17(6):477-480. 被引量:14
  • 2[1]Yuan HA,Garfin SR,Dickman CA,et al.A historical cohort study of pedicle screw fixation in thoracic,lumbar,and sacral spinal fusions[J].Spine,1994,19:22795~22965.
  • 3[2]Albumi K,Itoh H,Taneichi H,et al.Transpedicular screw fixation for traumatic lesion of the middle and lower cervical spine:Description of the techniques and preliminary report[J].J Spinal Disord,1994,7:19~28.
  • 4[3]Jeanneret B,Gebhard JS,Magerl F.Transpedicular screw fixation of articular mass fracture-separation:Results of an anatomical study and operative technique[J].J Spinal Disord,1994,7:222~229.
  • 5[5]Kotani Y,Cunningham BW,Abumi K,et al.Biomechanical analysis of cervical stabilization systems[J].Spine,1994,19:2529~2539.
  • 6[8]Miler RM,Ebraheim NA,Xu R,et al.Anatomic consideration of transpedicular screw placement in the cervical spine[J].Spine,1996,21:2317~2322.
  • 7[9]Ebraheim NA,XU R,Knight T,et al.Morphometric evaluation of lower cervical pedicle and its projection[J].Spine,1997,22:1~6.
  • 8[10]Hasegawa K,Homma T.Morphologic evaluation and surgical simulation of ossification of the posterior longitudinal ligament using helical computed tomography with three-dimensional and multiplanar reconstruction[J].Spine,1997,22(5):537~543.
  • 9[12]Ludwig SC,Kramer DL,Balderston RA,et al.Placement of pedicle screws in the human cadaveric cervical spine[J].Spine,2000,25:1655~1667.
  • 10[13]James S,Ralph C,Bernard Jeanneret.Safety and accuracy of transpedicular fixation C1~C2 using an aiming device[J].Spine,1998,23:2185~2189.

共引文献70

同被引文献15

  • 1刘景堂,唐天驷,刘兴炎,葛宝丰,王以进.两种长度的颈椎椎弓根螺钉与侧块螺钉拔出试验比较[J].中国脊柱脊髓杂志,2005,15(3):177-179. 被引量:18
  • 2Panjabi MM, Shin EK, Chen NC, et al. Internal morphology of human cervical pedicles[J]. Spine, 2000, 25(10) : 1 197 - 1 205.
  • 3Kotani Y, Cunningham BW, Abumi K, et al. Biomeehanical analysis of cervical stabilization systems. An assessment of transpeclicular screw fixation in the cervical spine [ J ]. Spine, 1994, 19 ( 22 ) : 2529 - 2539.
  • 4Ebraheim NA, Xu R, Knight T, et al. Morphometric evaluation of lower cervical pedicle and its projection[J]. Spine, 1997, 22(1) : 1 -6.
  • 5Kosmopouloa V, Schizas C. Pedicle screw placement accuracy: ameta - analysis[J]. Spine, 2007, 32(3) : 111 - 120.
  • 6Heiko KoUer Cervical anterior transpedicular screw fixation [ J ]. Eur Spine, 2008, 17 : 523 - 538.
  • 7Jones EL, HeUer JG, Silcox DH, et al. Cervical pedicle screws versus lateral mass screws. Anatomic feasibility and biomechanical comparison[J]. Spine, 1997, 22(9) :977 - 982.
  • 8Kosrnopoulos V, Schizas C. Pedicle screw placement accuracy: a meta- analysis[J]. Spine, 2007, 32(3) : 111 - 120.
  • 9Abumi K, Itoh H, Taneichi H, et al. Transpedicular screw fixation for traumatic lesions of the middle and lower cervical spine: description of the techniques and preliminary report [ J ]. J Spinal Disord, 1994, 7(1 ):19- 28.
  • 10Jeanneret B, Gebhard JS, Magerl F. Transpedicular screw fixation of articular mass fracture - separation: results of an anatomical study and operative technique [ J ]. J Spinal Disord, 1994, 7 (3):222- 229.

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部