摘要 以西气东输中卫压气站RF2 BB36型压缩机喘振线的测试为例,介绍了RF2/3BB36型压缩机喘振线的测试方法,同时对该测试方法存在的优缺点和适用性进行了总结。 Take the test for the surge line of RF2/3BB36 Gas Compressor in Zhongwei Gas Compressor Station for example,the paper introduces the test method of the surge line. Strong and weak points of this test method are exposed during testing. Authors consider that by means of testing the surge line of the newly-installed gas compressor set,its field performance is verified and the surge parameters measured is inputted into anti-surge control program at one time so as to ensure safe running of the gas compressor sets.
出处 《油气储运》 CAS 北大核心 2008年第7期49-51,共3页 Oil & Gas Storage and Transportation
关键词 西气东输管道 压缩机 喘振线 测试方法 West-to-East Gas Transmission Pipeline,Gas Compressor,surge line,test method