就目前冷却塔热力计算中,不同作者对蒸发水量带走热量系数K的处理及存在问题进行了分析研究,并提出了自己的见解。
The procedures for calculating the coefficent of bringing off heat due to evaporation of water from cooling towers adopted by different authors are analyzed. A new procedure for the purpose is presented.
出处
《西安建筑科技大学学报(自然科学版)》
CSCD
1997年第3期271-274,共4页
Journal of Xi'an University of Architecture & Technology(Natural Science Edition)
关键词
冷却塔
蒸发水量
热量系数
热力计算
工业给水
cooling tower, evaporated water, coefficient of bringing off heat, thermal calculation