期刊文献+

蚌埠卷烟厂控温厂房技改的节能设计与施工

The energy saving design and construction of Bangbu cigarette factory temperature control plant technical reformation
下载PDF
导出
摘要 根据某卷烟厂建筑结构和生产工艺现场实际情况,论述了墙体霉变的原因,进行了一系列热工计算、施工方案研究和工程造价比选,最后选择了钢丝网架聚苯板保温系统治理墙体冷凝和霉变,并指出该工法具有保温效果好、施工工艺简便、耐久性好等优点。 According to the field real situation of one cigarette factory architectural structure and production technology, it discusses the reasons of wall mold, and gets the thermal calculation, construction programs research and project cost comparison and selects the steel wire net frame polyphenyl plate heat insulating system manage the wall condensation and mold in the end, and points out that the method has the merits of good heat insulating effect, convenient construction technology and the good durability.
作者 郭传斌
出处 《山西建筑》 2008年第22期224-225,共2页 Shanxi Architecture
关键词 控温厂房 墙体保温 节能设计 霉变 temqerature control plant, wall heat insulating, energy saving design, mold