期刊文献+

非完全密封金属板电磁屏蔽方法分析 被引量:1

Analysis of Electromagnetic Shielding with a Incompletely Sealed Metal Plane
下载PDF
导出
摘要 防止电磁泄漏的屏蔽机柜往往因某些需要如板间接缝、开关孔、线缆孔、散热孔、仪表以及机械接头等,使屏蔽机柜带有缝隙(孔隙),这样,缝隙(孔隙)的电磁泄漏就会降低总的屏蔽效能。文中对非完全密封金属板的电磁屏蔽效能进行计算及分析,并给出一些有效方法与建议。 To prevent electromagnetic field from leaking out of usually shielded cabinet often fails because of some requirements such as the connection of planes, switch holes, cable connector holes, heat dipssipation holes, meter openings and machanical connections make the shielded machine cabinet have slots (holes). Thus, the electromagnetic leak of the slot (hole) will lower the shielding effect. This paper suggests mainly some effective methods to ~eal completely the metal holes and carries out the calculation and analysis of the shielding performance for incomplete shielded metal planes.
作者 陈建行 刘刚
机构地区 中国人民解放军
出处 《电子工程师》 2008年第7期28-30,共3页 Electronic Engineer
关键词 非完全密封金属板 电磁屏蔽 电磁泄漏 缝隙 孔隙 incompletely sealed metal plane electromagnetic shielding electromagnetic leakage slot hole
  • 相关文献

参考文献1

  • 1李海泉,等.可靠性可用性可维性[M].北京:清华大学出版社,1992.

同被引文献11

引证文献1

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部