期刊文献+

时间分辨荧光免疫分析仪器测量时间精度的提高

Improving of Time Measuring Precision in Time-resolved Fluoroimmunoassay Instrument
下载PDF
导出
摘要 介绍了时间分辨荧光免疫分析(Time-resolved Fluoroimmunoassay,TRFIA)的基本工作原理,分析了影响测量时间(tC)精度的主要因素,针对这些影响因素,采用了TX2108温度补偿晶体振荡器和双游标法提高测量时间精度的措施。最终,在保证同样测量精度的前提下,将所需测量次数由1000次减少到120次。 The working principle of Time-resolved Fluoroimmunoassay (TRFIA) is introduced. The primary aspects of swaying time (tc) measuring precision are analyzed. Time measuring precision is improved by using TCXO (temperature compensated crystal oscillators) and "double vernier" method. In the same measuring precision, measuring times are reduced form 1 000 to 120.
出处 《医疗卫生装备》 CAS 2008年第7期109-111,共3页 Chinese Medical Equipment Journal
关键词 时间分辨 荧光免疫分析 测时精度 游标 time-resolved fluoroimmunoassay time measuring precision vernier
  • 相关文献

参考文献5

二级参考文献81

  • 1游冬青,陈杞.镧系离子时间分辨荧光检测法在核酸分析技术中的应用[J].光电子技术与信息,1994,7(5):41-44. 被引量:5
  • 2[1]Uehar M, Arai Y, Watanabe's, et al. Compaarison of plasma and urinary phytoestrogens in Japanese and Finnish women by time-resolved fluoroimmunoassay[J] . Biofactors, 2000; 12(1 -4): 217 -225.
  • 3[2]Wang GJ, Lapcik O, Hampl R, et al. Time-resolved fluoroimmunoassay of plasma daidzein and genistein[J]. Steroids, 2000;65(6): 339 - 348.
  • 4[3]L'homme R, Brouwers E, Al-Maharik N, et al. Time-resolved fluoroimmunoassay of plasma and urine O-desmethylangolensin[J].Steroid Biochem Mol Biol, 2002; 81 (4 - 5): 353 - 361.
  • 5[4]Yamada H, Satoh R, Yamashita T, et al. Development of a time-resolved fluoroimmunoassay(TR-FIA) for testosterone:measurement of serun testosterone concentrations after testosterone treatment in the rainbow trout(Oncorhynchusmykiss)[J]. Gen Comp Endocrinol, 1997; 106(2): 181 - 188.
  • 6[5]Mehto P, Ankelo M, Hinkkanen A, et al.A time-resolved fluoroimmunoassay for the detection of microcystins, cyanobacterial peptede hepa to toxins[J]. Toxin, 2001; 39:831 - 836.
  • 7[6]Uehara M, Lapcik O, Hampl R, et al. Rapid analysis of phytoestrogens in human urine by time-resolved fluoroimmunoassay[J]. Steroid Biochem Mol Biol, 2000; 72(50:273 - 282.
  • 8[8]Ibrahim F, Giton F, Villette JM, et al. Plasma 11 beta-hydroxy- 4-androstene-3, 17-dine: comparison of tied-resolved using tritiated tracer[J]. Steroid Biochem Mol Biol, 2003; 84(5): 563 -568.
  • 9[9]Kobayashi M, Kimura H, Liao J, et al. Measurement of mouse urinary typeⅣ collagen using time-resolved fluoroimmunoassay[J].Anal Sci,2003; 19(2): 205 - 210.
  • 10[10]Fiet J, Giton F, Auzerie J, et al. Development of a new sensitive and specific time-resolved fluoroimmunoassay(TR-FIA) of chlormadinone acetate in the serum of treated menopausal women[J]. Steroids, 2002; 67 ( 13 - 14): 1045 - 1055.

共引文献54