期刊文献+

人工晶状体眼伪调节研究进展 被引量:6

Advanced research on pseudophakic accommodation of eyes with artificial lens
下载PDF
导出
摘要 许多白内障术后患者可以获得比实际预期要好的近视力,其中原因在于人工晶状体眼伪调节的存在。人工晶状体眼伪调节的测量方法主要包括:推进法、离焦法、动态检影法、红外线可视验光仪、视觉诱发电位法及利用A型超声或超声生物显微镜测量调节前后前房深度的变化间接测定调节幅度。人工晶状体眼伪调节的影响因素主要包括景深、人工晶状体位移、近视散光、像差、角膜的多焦性等。 With the increase of population and the coming of aging ,. more and more patients suffer from cataract and need to be treated by surgical operation. Meanwhile, as the development of society, for a better life, patients are being desirous not only to see clearly, but also to see comfortably. So, they paid more attention on artificial lens accommodation function after cataract operation. It was found that visual acuity of young patients was better than that of elders after cataract operation and many researchers had made much investigation before. We made a review on the research history, measurement methods and influence factors of artificial lens accommodation.
作者 吴宪巍 何伟
出处 《国际眼科杂志》 CAS 2008年第7期1423-1425,共3页 International Eye Science
关键词 白内障 人工晶状体 伪调节 artificial lens pseudophakic accommodation cataract
  • 相关文献

参考文献30

  • 1Bettman JW. Apparent accommodation in aphakic eyes. Am J OphthalmoI 1950 ;33:921-930.
  • 2Sugitani Y, Komori T, Katoh R. Apparent accommodation ( pseudoac- commodation) on pseudophakia. Floia Ophthalmol Jpn 1979 ;30:326-332.
  • 3Shuichi Y, Emiko AU. Apparent accommodation in Pseudophakic eyes as Measured with Visually Evoked Potentials. Invest Ophthalmol Vis Sci 1992 ;33:443-446.
  • 4Yamamoto S, Adachi-Usami E, Kuroda N. Accommodation power determined with transient pattern visual evoked cortical potentials in diabetes. Doc Ophthalmol 1989 ;72:31-37.
  • 5Michael K, Nhung X, Nguyen, et al. Impantation of a new Accommodative Posterior Chamber Intraocular Lens. J Refractive Surg 2002; 18: 208 -216.
  • 6Achim L. Accommodative response measures vary with different tests: researchers study pseudophakic patients with accommodative posterior chamber IOLs. Ophthalmology Times 2003 ; 15 : 134-137.
  • 7吴星路.人眼景深的研究[J].眼科研究,1984,2:209-213.
  • 8Loewenfild IE, The pupil: Anatomy physiology and clinical applications lsted. Ames:Iowa State University Press 1993:86.
  • 9Percival SPB, Setty SS. Prospectively randomized trial comparing the pseudoaccommodation of the AMO ARRAY multifocal lens and amonofocal lens.J Cataract Surg 1993 ; 19:26-31.
  • 10Eider MJ, Murphy C, Sanderson GF. Apparent accommodation and depth of field in pseudophakia.J Cataract Refract Surg 1996 ;22:615-619.

二级参考文献71