摘要 基于光学测头特征点成像的单目视觉坐标测量系统是一种新兴的高精度、大尺寸、三维整体、在线测试系统,在现代工业生产中具有重要应用价值。为评价这种单目视觉测量系统的测量精度,对基于测量不确定度的评定方法进行研究。在对影响单目视觉坐标测量系统测量精度的主要因素进行深入分析研究的基础上,建立测量不确定度评定表达式,实现对测量系统测量精度的评定;通过测量试验对评定方法加以验证,试验证明测量系统的测量精度与分析结果相吻合。 Single camera vision coordinate measurement system based on characteristic point imaging of optical probe is a newly arisen high-precision, large-size, 3-D integrated on-line measurement system and has important application value in the modem industrial production. To evaluate the measurement precision of the single camera vision measurement system, the evaluation method based on measurement uncertainty is studied. The evaluation expression is constructed by analyzing the main factor s of measurement precision of the single camera vision coordinates measurement system, and the evaluation of measurement precision is realized. Measurement experiment is done to verify the evaluation method, and which proves that the measurement precision of the measurement system tallies with the analysis result.
出处 《机械工程学报》 EI CAS CSCD 北大核心 2008年第7期75-78,共4页 Journal of Mechanical Engineering
基金 吉林大学校基金(419080101437) 吉林省科技发展计划(20070535)资助项目
关键词 视觉测量 测量不确定度 光学测头 扩展测量不确定度 Vision measurement Measurement uncertainty Optical probe Extended measurement uncertainty
  • 相关文献

参考文献9

  • 1ISO. Guide to the expression of uncertainty in measurement[S]. First edition. Switzerland: International Organization for Standardization, 1993.
  • 2FENG Changxue. Design and analysis of experiments in CMM measurement uncertainty study[J]. Precision Engineering, 2007, 31(2): 94-91.
  • 3张勇.坐标测量机长度测量示值误差不确定度分析[J].计量技术,2002(4):45-46. 被引量:1
  • 4ISO. Geometrical product specification (GPS)--acceptance and reverification tests for coordinate measuring machines (CMM)-parts: CMMS used for measuring size [S]. Switzerland ISQ 2001.
  • 5LIU Changying, HUANG Qingcheng, CHE Rensheng. Algorithm of single camera vision coordinates measuring based on features imaging of optical probe[C]//Proceedings of Third International Symposium on Instrumentation Science and Technology. Harbin: Harbin Institute of Technology Press, 2004, 3: 90-96.
  • 6LIU Changying, HUANG Qingcheng, CHE Rensheng. The study of optical feature point imaging gray value automation control method with movement[C]//Proceedings of SPIE--the Photonics Asia Conference on Light-Emitting Diode Materials and Devices, 2004. Bellingham.. International Society for Optical Engineering, 2004, 5 632: 296-303.
  • 7刘长英,黄庆成,车仁生,于之靖,叶东.光学特征点亮度控制方法研究[J].光学技术,2004,30(5):606-608. 被引量:3
  • 8叶东,刘长英,车仁生,陈刚.基于遗传算法的像机虚拟立体校准技术研究[J].光学精密工程,2006,14(3):485-489. 被引量:13
  • 9LIU Changying, CHE Rensheng, GAO Yinhan. High precision location algorithm for optical feature in vision measurement[C]//Journal of Physics : Conference Series 48. Manchester: Institute of Physics Publishing, 2006, 1 : 474-478.

二级参考文献12

  • 1ZHANG Y,OU ZH Y. A new linear approach for camera calibration[J]. Journal of Image and Graphics. 2001, 6(8): 727-731.
  • 2MENG X Q, HU ZH Y. A new easy camera calibration technique based on circular points[J]. Pattern Recognition.2003, 36: 1155-1164.
  • 3WENG J Y, COHEN P, HERNIOU M. Camera calibration with distortion models and accuracy evaluation[J].IEEE Trans on Pattern Analysis and Machine Intelligence, 1992, 14(10): 965-980.
  • 4HEIKKILA J ,SILVEN O. A Four-step camera calibration procedure with implicit image correction[J]. IEEE Proceedings of Computer Vision and Pattern Recognition. 1997, 1106-1112.
  • 5LIU CH Y,YU ZH J ,CHE R SH ,et al. Bundle adjustments CCD camera calibration based on collinearity equation[C]. Chinese Journal of Mechanical Engineering, 17:494-497.
  • 6LIU CH Y, YE D,CHE R SH, et al. The study of CCD camera optimization calibration technique using genetic algorithm[C]. Proceedings of Second International Symposium on Instrumentation Science and Technology(ISIST'2004), Xian, 2004. Harbin:Harbin Institute of Technology Press,2004.
  • 7SONGDE M. A self-calibration technique for active vision system[J]. IEEE Transactions on Robotics and Automation, 1996, 12:114-120.
  • 8KWON Y H,LINDLEY S L,SANDERS R H ,et al. Applicability of the localized-calibration methods in underwater motion analysis[C]. Proceedings of the XVIII International Symposium on Biomechanics in Sports, Hong Kong,China, 2000. Chinese University of Hong Kong Press ,2000.
  • 9JJF 1059-1999.测量不确定度评定与表示[S],1999.
  • 10朱光华,黄颂羽.GaAs红外发光二极管的可靠性研究[J].华东理工大学学报(自然科学版),1997,23(4):499-502. 被引量:1

共引文献14

同被引文献44

引证文献6

二级引证文献25

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部