期刊文献+

利用单吸气储液器改善双缸压缩机的声学性能 被引量:3

Amelioration of Acoustic Performance of Two-cylinder Compressors by Using Single-pipe Suction Accumulator
下载PDF
导出
摘要 压缩机是空调的主要噪声源之一,对其声学性能进行研究和改善很有必要。通过基于有限体积法的数值模拟得到了压缩机储液器内湍流压力脉动特性。由于旋转活塞的影响,靠近压缩机吸气入口压力脉动最剧烈,沿着竖管至储液器腔体逐渐减弱。充分利用了两根竖管内流体相位差180°的特点,将双管吸气改为带有两个旁支的单吸气储液器。数值计算表明单吸气储液器内压力脉动明显削弱,声学试验表明单吸气压缩机总声压级降低了约1.2dB(A),验证了数值计算结果和理论分析的正确性。 As the main contributor to the overall noise level of air-conditioners, the noise from the compressor is essential to be analyzed and suppressed. The wall pressure pulsations of accumulator are obtained through numerical simulations based on finite volume method, which shows that the highest pressure pulsation locates at the inlet of compressor and the lowest pressure pulsation is in the cavity of accumulator. Then the flow velocity phase difference of two pipes is utilized and the single-pipe accumulator with two branches is utilized for replacing the two-pipe suction accumulator. Numerical computation shows that turbulent pressure pulsations are greatly attenuated. The noise measurement shows the 1.2 dB(A) reduction for the single-pipe accumulator, which validates the numerical calculation and theoretical analysis.
出处 《机械工程学报》 EI CAS CSCD 北大核心 2008年第7期139-142,共4页 Journal of Mechanical Engineering
基金 国家自然科学基金(10674096)
关键词 储液器 压力脉动 双缸压缩机 声学性能 Accumulator Pressure pulsation Two-cylinder compressor Acoustic performance
  • 相关文献

参考文献9

  • 1ZHOU W, KIM J. Numerical prediction of radiated noise level from suction accumulators of rotary compressors[C]// Proc. of the 1998 Int. Compressor Conference, July, 1998, Purdue, America, 1998: 373-378.
  • 2XIANG H S, YE H H. Analysis of noise for accumulator of rotary compressor [C]//Proc. of the 4th International Symposium on Heating,Ventilating and Air Conditioning, October, 2003, Beijing, China, 2003: 940-944.
  • 3LEE J H, KIM J. Study on sound transmission characteristics of a cylindrical shell using analytical and experimental models [J]. Applied Acoustics, 2003, 64(6): 611-632.
  • 4YUN K W. Designing a function-enhanced suction accumulator for rotary compressor[C]//Proc, of the 1998 Int. Compressor Conference, July, 1998, Purdue, America, 1998: 655-659.
  • 5LEE S J, KIM H B. Quantitative analysis of flow inside the accumulator of a rotary compressor [J]. International Journal of Refrigeration, 2003, 26(3): 321-327.
  • 6YAKHOT V, ORSZAG S A. Renormalization group analysis of turbulence:Ⅰ Basic theory [J]. Journal of Scientific Computing, 1986, 1(1): 1-51.
  • 7SWADDIWUDHIPONG S, KHAN M S. Dynamic response of wind-excited building using CFD [J]. Journal of Sound and Vibration, 2002, 253(4): 735-754.
  • 8陶文铨.数值传热学[M].西安:西安交通大学出版社.2002.
  • 9POLACSEK C, DESBOIS F L. Fan interaction noise reduction using a wake generator: experiments and computational aeroacoustics [J]. Journal of Sound and Vibration, 2003, 265(4): 725-743.

共引文献29

同被引文献21

引证文献3

二级引证文献24

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部