摘要 目的评价动态移床3D-CE MRA 在糖尿病患者下肢动脉病变中的诊断价值。方法分析21例糖尿病患者下肢动脉的 MRA 检查结果,观察血管全貌、分支走行和狭窄的部位及范围等病变情况。比较3D-CE MRA 与 DSA 的分段符合率。结果 MRA 图像质量优者16例,质量良者5例;无图像质量差者。在10段血管中,MRA 发现动脉狭窄29处,DSA 发现36处,两者的总符合率为80.6%。两种检查诊断结果统计学兀显著性差异。结论动态移床3D CE-MRA 安全无创,对于糖尿病患者下肢动脉病变的诊断效果类似于 DSA,但更容易被患者接受。 Objective To explore the diagnostic value of MRA with a moving-bed infusion-tracking technique in lower limb arterial disease of diabetic patients. Methods MRA of low limb artery in 21 diabetes patients were analyzed. And the results were compared with that of DSA. Results 16 cases were excellent MR imaging and 5 were good. In 10 sections of low limb artery, 29 stenosis were displayed by MRA and 36 by DSA. The total accordance rate was 80.6%. There was no statistically significant difference between MRA and DSA in the diagnosis of stenosis. Conclusion MRA was a reliable method and non-invaslve method with excellent correlation between MRA and DSA in the diagnosis of arterial stenosis.
出处 《影像诊断与介入放射学》 2008年第4期188-190,共3页 Diagnostic Imaging & Interventional Radiology
关键词 磁共振血管成像 糖尿病 下肢动脉 MR angiography Diabetes Low limb artery
  • 相关文献

参考文献5

  • 1Apelqvst J, Larsson J.What is the most effective way to reduceincidence of amputation in the diabetic foot. Diabetes Metab Res Rev, 2000,16(Suppl) : 75-83.
  • 2Kreitner KF, Kalden P, Neufang A, et al. Diabetes and peripheral arterial occlusive disease: prospective comparison of contrast-enhanced three--dimensional MR angiography with conventional digital subtraction angiography. AJR, 2000, 174:171-179.
  • 3Kalle TV, Gedach A, Hatopp A, et al. Contrast-enhanced MR angiography (CEMRA) in peripheral arterial occlusive disease (PAOD): conventional moving table technique versus hybrid technique. ROFO, 2004, 176:62-69.
  • 4Gustav A, Thomas P, Kerstin G, et al. Peripheral Arteries in Diabetic Patients: Standard Bolus-Chase and Time-resolved MR Angiography. Radiology, 2007, 242: 610-620.
  • 5柴萌,张海涛,罗惠兰,谈维洁,黄丛春,朴龙松,齐自荣,刘朝中.MRA在糖尿病下肢血管病变中的诊断价值:与DSA对照研究[J].中国医学影像技术,2006,22(12):1870-1872. 被引量:12

二级参考文献6

  • 1强沁晨,杜湘珂,石坚,宋奕宁,李建国.彩色多普勒超声结合三维动态增强磁共振血管造影诊断下肢动脉硬化闭塞症[J].中国医学影像技术,2005,21(6):887-889. 被引量:9
  • 2Apelqvst J,Larsson J.What is the most effective way to reduce incidence of amputation in the diabetic foot[J]? Diabetes Metab Res Rev,2000,16(Suppl):S75-S83.
  • 3Steffens JC,Schafer FK,Oberscheil B,et al.Bolus-chasing contrast-enhanced 3D MRA of the lower extremity[J].Acta Radioligica,2003,44(2):185-192.
  • 4Cronberg CN,Sjoberg S,Albrechtsson U,et al.Peripheral arterial disease.Contrast-enhanced 3D MR angiography of the lower leg and foot compared with conventional angiography[J].Acta Radiol,2003,44(1):59-66.
  • 5Faglia E,Favales F,Quarantiello A,et al.Angiographic evaluation of peripheral arterial occlusive disease and its role as a prognostic determinant for major amputation in diabetic subjects with fool ulcers[J].Diabetes Care,1998,21(4):625-630.
  • 6王宁霞,刘斯润,王晓白,罗羽宏.下肢外周血管疾病诊断DSA和MRA(MobiTrack)的应用及选择[J].中国医学影像技术,2000,16(11):1015-1016. 被引量:13

共引文献11

同被引文献15

  • 1杨春山,张松,刘士远,肖湘生,周康荣,王金林,李惠民,肖珊,龚万庆.三维高时间分辨率动态增强MR血管成像在临床的初步应用[J].中华放射学杂志,2007,41(3):304-307. 被引量:8
  • 2王翠艳,赵斌,王光彬,张增芳,邱秀玲.三维增强MR血管成像在周围型动脉闭塞症分级中的应用价值[J].中华放射学杂志,2007,41(6):598-601. 被引量:11
  • 3Heiss SO, Shifrin RY. Contrast- enhanced three- dimensional fast spoiled gradient- echo ranal MR imaging: Evalutiong of vascular and nonvascular disease[J]. Radiographics, 2000, 20 (5) : 1341 - 1352.
  • 4Gustav A, Thomas P, Keistin G, et al. Peripheral arteries in diabetic patients : Standard bolus - chase and time - resolved MR angigraphy[J].Radio logy, 2007,242 : 610 - 620.
  • 5Fenchel M, Requardt M, Tomaschko K, et al. Whole - body MR angiography using a novel 32 - receiving - channel MR system with surface coil techology:First clinical experience[J]. J Magn Resonimaging,2005,21:596 - 603.
  • 6吴在德;吴肇汉.外科学[M]北京:人民卫生出版社,2004632.
  • 7Hideki Ota,Vasily L,Yarny KH. Carotid intraplaque hemorrhage imaging at 3.0-T MR imaging:comparison of the diagnostic performance of three T1-weighted sequences[J].Radiology,2010,(254):551-563.
  • 8Haider CR,Glockner JF,Stanson AW. Peripheral vasculature:high-temporal-and high-spatial-resolution three-dimensional contrast-enhanced MR angiography[J].Radiology,2009,(253):831-843.
  • 9Gustav A,Thomas P,Keistin G. Peripheral Arteries in Diabetic Patients:Standerd Bolus-chase and Time-resolved MR Angigraphy[J].Radiology,2007,(02):610-620.
  • 10Fenchel M,Requardt M,Tomaschko K. Whole-body MR angiography using a novel 32-receiving-channel MR system with surface coil techology:firstclinical experience[J].Journal of Magnetic Resonance Imaging,2005,(03):596-603.

引证文献2

二级引证文献14

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部