摘要 目的本研究比较了试验性增强法与常规增强法在肝脏CT动态增强扫描中的应用情况,探讨了试验性增强法在肝脏CT动态增强中的应用价值。方法对425倒接受肝脏CT动态增强扫描检查的患者进行回顾性分析。其中第一组203人次按常规方法行CT动态增强(在静脉开始注射造影剂后14~18s进行动脉期扫描),第二组222人次接受试验性增强法CT动态增强检查。比较、分析两组增强结果。结果第一组57.1%(116/203)的病例获得了最佳的肝动脉期图像,第二组87.4%(194/222)的病例获得了最佳的肝动脉期图像。统计学分析两组肝动脉期图像质量优良率的差异具有统计学意义。结论试验性增强法肝脏CT动态增强扫描对于肝脏动脉期的显示优于常规CT动态增强检查法。 Objective The purpose of this study was to identify the usefulness of the test - injection method as compared with the fixed - time method in dynamic CT of liver. Methods 425 patients have been studied that underwent dynamic CT. 203 patients (group 1 ) accepted the fixed -time method (14 -18 seeond scan time delay in the hepatic arterial phase [ HAP] ). 222 patients ( group 2) accepted the test - injection method. The adequacy of the HAP was evaluated. Result In group 1, 57.1% ( 116/ 203 )of the cases were obtained at the optimal HAP; the percentage in group 2 was 87.4% (194/222)of the eases. This difference was statistically significant (p 〈 0. 05 ). Conclusion The CT using the test - injection method resulted in better optimal HAP than the CT using the fixed - time method.
出处 《现代医院》 2008年第8期60-61,共2页 Modern Hospitals
关键词 CT 试验性增强法 常规增强法 肝动脉期 CT, Test- injection method, Fixed- time method, Hepatic arterial phase
  • 相关文献

参考文献7

  • 1YAN F H, SHEN J Z, LI R C, et al. Enhancement patterns of small hepatocellular carcinoma shown by dynamic MRI and CT [J]. Hepatobiliary Pancreat Dis Int, 2002,1 (3) :420 -424.
  • 2UEDA K, MATSUI O, KAWAMORI Y, et al. Hypervascular hepatocellular carcinoma; evaluation of hemodynamies with dynamic CT during hepatic arteriography[J]. Radiology, 1998, 206 (1): 161-166.
  • 3VAN BEERS B E, MATERNE R, LACROSSE M, et al. MR imaging of hypervaseular liver tumors: timing optimization during the arterial phase[J]. J Magn Reson Imaging, 1999, 9(4): 562- 567.
  • 4TORREGGIANI W C, VARGHESE J, HASLAM P, et al. Prospective comparison of MRA with catheter angiography in the assessment of patients with aortoiliae occlusion before surgery or endovaseular therapy [ J ]. Clln Radiol, 2002, 57 (7) :625 - 631.
  • 5SHINOZAKI K, YOSHIMITSU K, IRIE H, et al. Comparison of test - injection method and fixed - time method for depiction of hepatocellular carcinoma using dynamic steady - state free precession magnetic resonance imaging[J]. Journal of Computer Assisted Tomography, 2004, 28(5) : 628 -634.
  • 6赵虹,周康荣,严福华.肝脏多层螺旋CT扫描:不同注射流率对肝脏对比剂循环时间影响的探讨[J].中华放射学杂志,2004,38(1):82-85. 被引量:37
  • 7马吉伟,陈美荣,刘玉元,宋振龙.肝脏螺旋CT增强扫描的最佳延时时间[J].实用医学影像杂志,2003,4(2):81-82. 被引量:10

二级参考文献5

  • 1Brind JA, Heiken JP, Forman HP, et al. Hepatic spiral CT: reduction of dose of intravenous contrast material. Radiology, 1995, 197(1):83 ~86.
  • 2Berland LL, Lee JY. Comparison of contrast media injection rates and volumes for hepatic dynamic incremented computed tomography. Invest Radiol, 1988, 23 (3): 918 ~ 921.
  • 3Berland LL. Slip -ring and conventional dynamic hepatic CT,contrast material and timing consideration. Radiology, 1995, 195(1):1~8.
  • 4Chamber TP, Baron RL, Lush RM. Hepatic CT enhancement(Part Ⅰ)Alteration in the volume of contrast material within the same patients. Radiology, 1994, 193 (2): 513 ~ 519.
  • 5Joern J. Sandstede,Alexander Tschammler,Meinrad Beer,Carsten Vogelsang,Guenther Wittenberg,Dietbert Hahn. [J] 2001,European Radiology(8):1396~1400

共引文献42

同被引文献8

引证文献2

二级引证文献7

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部