摘要
目的建立保健食品及饮料中维生素C的高效液相色谱检测方法。方法ODS C18 5μm反相色谱柱分离,流动相和试样提取液为0.1%草酸溶液。紫外检测器,流速1.0ml/min,检测波长262nm。结果线性范围为0.05—700.00μg/ml。加标回收率为84.2%-94.9%,RSD〈10%,检出限为0.05 μg/ml。结论本方法操作简便、快速、数据可靠,适合于饮料及保健食品中的维生素C含量测定。
Objective To develop a RP-HPLC method to detect the content of vitamin C in health foods and drinks. Method The samples were extracted and eluted by 0.1% oxalic acid solution on a ODS C18 5 μm column at the flow rate of 1.0 ml/min at 262 nm. Results The good linear relationship was obtained over the range of 0.05 - 700 μg/ml. The average recovery ranged from 84.2% to 94.9%, and the RSD of the values of repeatability was less than 10% . The detection limit of the method was 0.05 μg/ml. Conclusion The method could be simple, fast and feasible, and it could be used to detect the content of vitamin C in health foods and drinks.
出处
《中国食品卫生杂志》
2008年第4期311-313,共3页
Chinese Journal of Food Hygiene
关键词
营养保健品
饮料
抗坏血酸
色谱法
高压液相
Dietary Supplements
Beverages
Ascorbic Acid
Chromatography, High Pressure Liquid