期刊文献+

多层螺旋CT鼻咽癌灌注研究 被引量:1

The primary report of multi-slice helical CT perfusion imaging in nasopha-ryngeal carcinoma
下载PDF
导出
摘要 目的:探讨鼻咽癌多层螺旋CT灌注成像的价值。方法:采用Siemens Emotion6多层螺旋CT机对22例鼻咽癌,l1例鼻咽炎症及20例无鼻咽疾病患者进行鼻咽灌注扫描,用其专用灌注软件perfusion灌注软件分别测量血流量(blood flow,BF)、血容量(blood volume,BV)、峰值时间(time to peak,TP)等指数,以评价鼻咽癌的血流动力学改变及其规律性。结果:鼻咽癌组BF、BV、TP95%可信区间分别为131.29~178.98ml/(min·100g),20.30~27.18ml/100g,19.77~25.60s,鼻咽炎症BF、BV、TP95%可信区间分别为(78.66±29.56)ml/(min·100g),(15.66±11.87)ml/100g,19.01~29.17s,正常对照组BF、BV、TP95%可信区间分别19.02~33.39ml/(min·100g),4.58~7.59ml/100g,18.00~25.20s。鼻咽癌、鼻咽炎症及对照组BF、BV统计学有显著性差异。结论:CT灌注成像可用于评价鼻咽癌及鼻咽炎血流灌注情况,有助于鼻咽癌的鉴别诊断及制定治疗方案。 Objective: To study the parameters of CT perfusion imaging of nasopharyngeal cancer(NPC). Methods:CT perfusion imaging of nasopharynx was obtained in 53 individuals, including 22 patients with NPC, 11 cases of inflammation and 20 control subjects.Perfusion parameters such as blood flow(BF),blood volume(BV)and time to peak(TP) were calculated. Results: The 95% confidence intervals of BF, BV and TP of NPC group were 131.29-178.98 ml(min·100 g), 20.30-27.18 ml/100 g,19.77-25.60 s, that of inflammation group was(78.66±29.56) ml/(min·100 g), (15.66±11.87) ml/100 g, 19.01-29.17 s and that of control group was 19.02-33.39 ml/(min·100 g), 4.58-7.59 ml/100 g, 18.00-25.20 s. The value of BF and BV had significant difference between NPC, inflammation and control group.Conclusion:CT perfusion imaging can be a new method to evaluate the blood supply of NPC.
出处 《中国医药导报》 CAS 2008年第22期18-19,81,共3页 China Medical Herald
基金 江门市科技局科技计划项目(编号20051002)
关键词 鼻咽癌 灌注研究 多层螺旋CT Nasopharyngeal cancer Perfusion study Multi-slice helical CT
  • 相关文献

参考文献9

  • 1[1]Harvey CJ,Blomley MJ,Dawson P,et al.Functional CT imaging of the acute hyperemic response to radiation therapy of the prostate gland:early experience[J].J Computered Assist Tomogr,2001,25(1):43-49.
  • 2赵心明,周纯武,吴宁,罗德红,黄遥,王建卫,孙伟,梁颖.胰腺多层螺旋CT灌注研究[J].中华放射学杂志,2003,37(9):845-849. 被引量:90
  • 3张菁,漆剑频,陈浪,黄文华.多层螺旋CT灌注成像对脑肿瘤血管通透性的研究[J].临床放射学杂志,2004,23(8):655-658. 被引量:20
  • 4[4]Dugdale PE.Miles KA,Bunce I,et al.CT measurement of perfusion and permeability within lymphoma masses and its ability to assess grade,activity,and chemotherapeutic response[J].J Computered Assist Tomogr,1999,23(4):540-547.
  • 5[5]Brix G,Babner ML,Hoffmann U,et al.Regional blood flow,capillary permeability.and compartmental volumes:measurement with dymamic CTinitial experience[J].Radiology.1999,210(1):269-276.
  • 6[6]Miles KA,Griffiths MR,Fuentes MA.Standardized perfusion value:universal CT contrast enhancement scale that correlates with FDG PET in lung nodules[J].Radiology,2001,220(2):548-553.
  • 7[7]Purdie TG,Henderson E,Lee TY.Functional CT Imaging of angiogenesis in rabbit VX2 soft-tissue tumour[J].Phys Med Biol,2001,46(12):3161-3175.
  • 8[8]Miles KA.Perfusion CT for the assessment of tumor vascularity[J].Br J Radiol,2003,76(1):36-42.
  • 9[9]Arkadiusz Sitek,Robert G.Perfusion measurement:feasibility with single-compartment kinetic model applied to dynamic contrast enhanced CT[J].Radiology,2005,237(1):670-674.

二级参考文献25

  • 1Yeung WT, Lee TY, Del Maestro RF, et al. Effect of steroids on iopamidol blood-brain transfer constant and plasma volume in brain tumors measured with X-ray computed tomography. J Neurooncol, 1994,18:53
  • 2Ford J, Miles K, Hayball M, et al. A simplified method for measurement of blood-brain barrier permeability using CT: preliminary results and the effect of RMP-7. In: Faulkner K et al. editors. Quantitative imaging in oncology. London: British Institute of Radiology, 1
  • 3Miles KA, Hayball MP, Dixon AK. Color perfusion imaging: a new application of computed tomography. Lancet, 1991, 337:643
  • 4Hamberg LM, Hunter GJ, Halpern EF, et al. Quantitative high resolution measurement of cerebral vascular physiology with slip-ring CT.AJNR, 1996, 17:639
  • 5Tereda T, Nambu K, Hyotani G, et al. Cerebral blood flow: a method for quantitative measurement of cerebral vascular permeability using Xray CT and iodinated contrast medium. Neuroradiology, 1992, 34:290
  • 6Cenic A, Nabavi DG, Graen RA, et al. Dynamic CT measurement of cerebral blood flow: a validation study. AJNR 1999, 20:63
  • 7Nabavi DG, Cenic A, Dool J, et al. Quantitative assessment of cerebral hemodynamic using CT: Stability, accuracy, and precision studies in dogs. J Comput Assist Tomogra, 1999, 23:506
  • 8Lee TY, Nabavi DG, Graen RA, et al. Validation of cerebral blood flow maps from contrast-enhanced cine CT scanning: comparison of infarct size from TTC staining and blood flow threshold in a rabbit focal cerebral ischemia model. Radiology, 2000, 213:1305
  • 9Cenic A, Nabavi DG, Graen RA, et al. A CT method to measure hemodynamics in brain tumors: validation and application of cerebral blood flow maps. AJNR, 2000, 21:462
  • 10Fong TAT, Shawver LK, Sun L,et al. SU5416 is a potent and selective inhibitor of the vascular endothelial growth factor receptor (Flk-1/KDR)that inhibits tyrosine kinase catalysis, tumorvascular-ization, and growth of multiple tumor types. Cancer Res, 1999, 59:99

共引文献107

同被引文献17

引证文献1

二级引证文献5

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部