摘要 精确时钟协议IEEE1588在分布式控制系统中应用广泛。但是在基于并行化网络冗余的分布式控制系统中,IEEE1588协议由于在状态机设计中没有考虑网络冗余的情况,由于同步线路延时计算偏差,造成网络冗余系统的时钟同步存在切换扰动,导致系统在冗余网络切换过程中出现同步偏差。本文在深入分析了IEEE1588协议在网络冗余系统中造成切换扰动的原因。并且,在兼容IEEE1588协议基础上,提出了网络冗余时钟同步方式,以及基于该方法的冗余同步优化算法,解决了冗余网络切换过程中时钟同步的偏差。 Precise clock protocol IEEE1588 is used widely in distributed control systems. Because of the bug in protocol state machine design, IEEE1588 causes redundancy switch disturbance in network redundancy distributed system. This paper analyzes deeply the mechanism that causes redundancy switchover disturbance, and raises a method for achieving clock synchronization in network redundancy system based on IEEE1588, and proposes an optimization arithmetic, which solves the clock synchronization deviation in switch process of redundancy network.
出处 《仪器仪表学报》 EI CAS CSCD 北大核心 2008年第8期1643-1649,共7页 Chinese Journal of Scientific Instrument
基金 国家创新群体基金(NCRGSFC:60421002)资助项目
关键词 网络冗余 时钟同步 线路延时 network redundancy PTP network delay
  • 相关文献

参考文献9

二级参考文献19

  • 1王忠锋,于海斌,王宏,徐皑冬,周侗.工业以太网确定性通信实现方案[J].仪器仪表学报,2005,26(z1):491-492. 被引量:6
  • 2Richard R. Larson. AFTI/F-111 MAW flight control system and redundancy management description [M].NASA, February 1987. 21-36.
  • 3IEEE1588,Standard for a Precision Clock Synchronization Protocol for Networked Measurement and Control Systems[S].IEEE1588-2002 Standard,November 2002.
  • 4Dirk S.Mohl.IEEE1588-Precise Time Synchronization as the Basis for Real Time Applications in Automation[J].Industrial Networking Solutions,2003.
  • 5The NetWork Time Protocol(NTP)Distribution[S].March 2004.
  • 6Eidson J C,Hamilton B.IEEE-1588 Node Synchronization Improvement by High Stability Oscillators[J].Workshop on IEEE-1588,Standard for a Precision Clock Synchronization Protocol for Networked Measurement and Control Systems,2003,102-112.
  • 7Mohl D.IEEE1588:Running Real-time on Ethernet[OL].http://ethernet.industrial-networking.com/articles/i17real-time.asp.
  • 8ISO/IEC 9646-1 to 7-1994 Information Technology-Open Systems Interconnection-Conformance Testing Methodology and Framework[S].1994.
  • 9国家质量技术监督局.用于工业测量与控制系统的EPA系统结构与通信规范(报批稿)[S].2005-08.
  • 10IEC/PAS 62409-2005 Real Time Ethernet EPA (Ethernet for Plant Automation)[S].2005.