摘要 通过对热泵热水机组的年供热性能系数的计算、对医院热水用量的计算及不同热水机组的产热所需的费用的计算,可以总结出冷水机组的热回收与热泵热水机组相结合所产生的经济效益是非常大的。 Through the computation of annual hot water heating coefficient of performance of heat pump, hot water demand in hospital and the heating expenses of different water heaters, summarizes the economic benefit which water chiller's heat recovery in combination with heat pump water heater produces is great.