期刊文献+

超高效液相色谱/串联质谱法测定水体中灭草松的含量 被引量:13

Determination of Bentazone in Water Using Ultra-high Performance Liquid Chromatography-electrospray Tandem Mass Spectrometry
下载PDF
导出
摘要 灭草松是一种触杀型具选择性的苗后除草剂,对环境和人类的饮用水安全造成很大的危害。建立了固相萃取(SPE)-超高效液相色谱/串联质谱法(UPLC/MS/MS)检测水中灭草松的方法。方法对灭草松的检出限为0.2 ng/L,平均回收率为80.1%,相对标准偏差(RSD)为5.2%,线性范围为0.1-10 μg/L。应用该法分析了部分城市地表水,取得满意结果,具有一定的实用性。 A method for analysis of bentazone in water was developed using solid phase extraction and ultra-high performance liquid chromatography-electrospray tandem mass spectrometry. The linear relationship between peak area and concentration of bentazon holds was found in the range of 0.1-10 ug/L. Detection limit of the method was 0.2 ng/L. The relative standard deviation (n=6) was 5.2%. The average recovery of bentazone was around 80.1%. The optimized method was successfully applied to the analysis of surface water.
出处 《农药》 CAS 北大核心 2008年第8期586-587,589,共3页 Agrochemicals
关键词 灭草松 水体 固相萃取 超高效液相色谱 串联质谱 bentazone water solid phase extraction UPLC/MS/MS
  • 相关文献

参考文献5

二级参考文献7

  • 1国家商检局FDA—PAM编译组编译.美国食品药物管理局农药残留量分析手册[M].长沙:湖南科学技术出版社,1989.680-681.
  • 2Kenneth W. Edgell and Elizabeth J. Erb, Gas Chromatographic/Electron Capture Detection Melhod for Determination of Chlorinated Acids in Water:Collaborative Study. Journal OF AOAC, 1993, Vol. 76, No5,652 - 656..
  • 3Christian W.Thorstensen and Agnethe Christiansen,Determination of Bentazone,Dichlorprop,and MCPA in Different Soils by Sodium Hydroxide Extraction in Combination with Solid-Phase Preconcentration[J].J Agric Food Chem,2001,49(9) :4199~4202.
  • 4SN 0292-1993,出口粮谷中灭草松残留量检验方法[S].
  • 5李克斌,刘维屏,许中坚,马云.灭草松在腐殖酸上的吸附及其机理[J].环境科学学报,2002,22(6):754-758. 被引量:17
  • 6韩见龙,汤均.气相色谱法测定水中灭草松[J].中国卫生检验杂志,2003,13(3):308-310. 被引量:12
  • 7吕云波,杨长志,李湘彬.气相色谱法测定粮谷中灭草松残留量[J].农机化研究,2003,25(4):191-192. 被引量:5

共引文献28