期刊文献+

浅谈建筑消防设施施工的通病 被引量:6

Notes for the common faults in fire prevention facilities in the construction process
下载PDF
导出
摘要 阐述了建筑消防设施室内消火栓系统方面的通病,从施工队伍人员素质、管材和设备质量两方面分析了通病的根源,在此基础上提出了合理对策,并指出施工质量的好坏直接影响着建筑消防设施的正常运行。 The paper analyzes the common faults of the fire prevention facilities in the respect of the indoor hydrant system and analyzes the reasons for these faults from two respects, the quality of the construction team and the quality of the tubular products and equipment, On the base of the above-mentioned part, the paper points out the rational strategies and indicates the quality of the construction will influence directly on the failure-free operation of the fire prevention facilities.
作者 韩军龙
出处 《山西建筑》 2008年第23期188-188,共1页 Shanxi Architecture
关键词 建筑消防设施 消火栓系统 通病 施工质量 对策 fire prevention facilities, hydrant system, common faults, construction quality, strategies