摘要
总结国产化大氮肥二期液氮洗装置试车及开车以来的运行情况,针对设计及开车过程中出现的问题,提出解决办法和防范措施,消除了缺陷和隐患,保证了装置安全稳定运行。
This article summarizes the operation of the second-phase liquid nitrogen washing plant of Chinese-buih large nitrogenous fertilizer since its commissioning and startup. Aimed at the problems existed in design and startup, proposed solutions and preventive measures, eliminated defects and hidden danger, and guaranteed safe and stable operation of the plant.
出处
《大氮肥》
CAS
2008年第2期138-140,共3页
Large Scale Nitrogenous Fertilizer Industry
关键词
液氮洗装置
事故分析
解决措施
liquid nitrogen washing plant, failure analysis, solutions