摘要 目的探讨钼靶X线导丝定位手术活检技术在隐匿性乳腺病灶诊断中的价值。方法利用专用计算机立体定位系统,对47个临床不能触及的乳腺隐匿性病灶行钼靶X线导丝定位术,在导丝引导下手术切除病灶并对切除组织进行钼靶摄影,确定病灶被完全切除后送病理检验。结果45例患者,计有隐匿性病灶47个,留置导丝47根,导丝引导下手术活检均一次性成功,且病灶被完整切除,诊断正确率为100%。病理结果:乳腺癌13例14个病灶,其中1例为双侧乳腺癌;良性病变32例33个病灶。结论钼靶X线导丝定位手术活检技术简便易行、定位准确,能确定乳腺隐匿性病灶的性质,可提高早期乳腺癌的诊断率。 Objective Approach mammographic wire-localization biopsy technology's value in diagnose of delitescence focus of infection about breast disease. Methods Utilizing specific purpose computer stereotaxis system, utilize mammographic wire-localization for 47 pieces delitescence focus of infection about breast disease which can't be touched in clinical,at guide wire's leading exsect focus of infection and make molybdenum target for tissue by excisional,then make patho-test when the focus of infection were completely resection. Results 45 patients have 47 pieces delitescence focus of infection, detaining 47 guide wire, all operations succeed only by once, and the focus of infection are completely resectlon,the correct rate of diagnose is 100 %. The result of patho: 13 cases are breast cancer and that have 14 pieces focus of infection, one of them is both sides, benign lesion are 32 cases and 33 pieces focus of infection. Conclusion The biopsy by mammographic wire-localization is convenient and accurate,can make sure the character of delitescence focus of infection about breast disease, which can raise the rate of diagnosis in earlier period breast cancer.
作者 汪建华 张剑
出处 《中国基层医药》 CAS 2008年第7期1063-1064,共2页 Chinese Journal of Primary Medicine and Pharmacy
关键词 乳腺疾病 钼靶X线导丝定位 活组织检查 Breast disease Mammographic wire-localization Biopsy
  • 相关文献

参考文献6

二级参考文献14

  • 1郭榆江,黄燮民,邹强,张浩,陶国清.保乳手术治疗早期乳腺癌57例临床分析[J].中国综合临床,2004,20(6):544-545. 被引量:4
  • 2张嘉庆,王殊.乳腺外科新技术的发展与展望[J].中国普外基础与临床杂志,2005,12(3):201-203. 被引量:18
  • 3王仁启.早期乳腺癌保守性手术治疗12例分析[J].中原医刊,2005,32(21):1-2. 被引量:2
  • 4孙晓宇.乳腺癌的保留乳房手术及哨兵淋巴结活检分析[J].医药世界,2006(4):84-85. 被引量:2
  • 5Olin LJ, Fouxquet A, Vicini FA. Mammographically detected duetal carcinoma in situ of the breast irradiation: long-term outcome and prognostic significance of patient age and margin status. Int J Radiat Oncol Biol Phys,2001,50(4) :991-1002.
  • 6Jatol I. Management of the axilla in primary breast cancer. Surg Clin North Am, 1999,78 : 1061-1073.
  • 7Memasters KM, Giuliano AE, Ross MI, et al. Sentinel-iymph-node biopsy for breast cancer not yet the standard of care. N Eng J Med,1998,339 : 990-995.
  • 8Veronesi U, Paganelli V,Galimberti V, et al. Sentinel-node biopsy to avoid axillary dissection in breast cancer with clinically negative lymph nodes. Lancet, 1997, 349 : 1864-1867.
  • 9Kollisa J, Gill PG, Coventry BJ, et al. Clinical and histological factors associated with sentinel node identification in breast cancer.Aust N Z J Surg, 2000,70:485-489.
  • 10Bostiek PJ, Chatterjee S, Chi DD, et al. Limitations of specific reveme-transcriptase polymerase chain reaction markers in the detection of metastases in the lymph nodes and blood of breast cancer patients. J Clin Oncol, 1998,16 : 2632-2640.

共引文献38

同被引文献9

  • 1海健,毛杰,刘少华,唐利立,申正堂.隐匿性乳腺癌的诊断和治疗(附24例报告)[J].中国医师杂志,2006,8(3):386-387. 被引量:3
  • 2Sickles EA.Quality assurance:how to audit your own mammography practice.Radial Clin North Am,1992,2:187.
  • 3Gary JB,Maj JBG,Maj RH,et al.Nonpalpable breast lesion:association of mammographic abnomalities with diagnosis after needie-directed biopsy.South Med,1993,86:74.
  • 4李树玲.乳腺肿瘤学.北京:北京科学技术文献出版社,2002:210-212,616-617.
  • 5powell R W,Mcsweeney MB,Wilson CE.X-ray calcifications as rhe only basis for breast biopsy.Ann Surg,1986,197:555.
  • 6阚秀.乳腺癌临床病理学.北京:北京医科大学、中国协和医科大学,1993:84.
  • 7徐开林主编.乳腺疾病影像诊断与治疗学.上海:上海科技教育出版社,1996.15.
  • 8陈焕泽,郑雪芳.隐匿性乳腺癌的钼靶X线诊断[J].浙江临床医学,2008,10(11):1491-1492. 被引量:4
  • 9殷汉民.乳腺浸润性导管癌X线表现[J].放射学实践,2000,15(6):428-430. 被引量:9

引证文献1

二级引证文献5

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部