摘要 湿法烟气脱硫系统是否设置GGH,是目前国内争议较大的问题,其对脱硫系统的投资和经济运行有重大影响。针对三水恒益电厂600 MW机组安装脱硝系统(SCR)之后,石灰石—石膏湿法烟气脱硫系统是否安装GGH进行了探讨,为工程初步技术设计提供参考。 The poinion of gas gas heater provided in the wet flue gas desulfurization system has big disputes in domestic at present. It has significant influence on the investment and economic operation of the desulfurization system. The installation of GGH on the FGD system with limestone - gypsum process after taking the denitrification device ( SCR ) of Hengyi Power Plant 600 MW units at Sanshui district has been discussed. It may provide reference for the similar FGD engineering preliminary design,
出处 《电力环境保护》 2008年第4期17-19,共3页 Electric Power Environmental Protection
关键词 湿法烟气脱硫 GGH SCR wet FGD gas gas heater SCR
  • 相关文献

参考文献8

二级参考文献20

  • 1张华,何强,陈振宇,陈玉乐.湿法烟气脱硫中GGH对污染物扩散影响初探[J].电力环境保护,2005,21(2):1-3. 被引量:43
  • 2许正涛,吴树志,范新宽.湿法烟气脱硫系统不设GGH的经济性及对环境影响的分析[J].电力环境保护,2005,21(2):57-59. 被引量:28
  • 3赵鹏高,马果骏,王宝德,胡健民.湿法烟气脱硫工艺是否安装烟气换热器问题探讨[J].电力环境保护,2005,21(4):19-21. 被引量:18
  • 4谭亚南.湖南某电厂2×600MW机组环境影响评价报告书[R].,2005.5..
  • 5国家环保总局环境工程评估中心.环境影响评价技术方法[M].,2005..
  • 6郝吉明 王书肖 陆永琪.燃煤二氧化硫污染控制技术手册[M].北京:化学工业出版社,2002..
  • 7Radian International LLC. Electricutility engineer's FGD manual[M].US DEO, 1998.
  • 8Walter Nischt, Jeff Hinos, Kevin Robison, et al. Selective catalytic reduction retrofit of a 675MW boiler at AES someset[R].ICAC NOx forum, Washington D C, 2000.
  • 9Roges K, Nolan P. SCR reactor performance profiling and results analysis, US EPA/DOE/EPRI combined power plant air pollutant control symposium:"The Mega symposium"[R]. USA:Chicago, 2001.
  • 10范从振.烟炉原理.北京:水利电力出版社,1992.4.

共引文献75

同被引文献15

引证文献2

二级引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部