期刊文献+

新技术在125MW机组电除尘器改造中的应用 被引量:1

Application of electrostatic precipitator new technology in 125MW units ESP reformation
下载PDF
导出
摘要 介绍了高频电源、分区供电的技术特点。针对贵州华电遵义发电有限公司8号炉125 MW机组电除尘器存在的高风速问题,在不增加断面的情况下对其进行改造,从本体结构及电气方面着手,提高电场的运行电压与电流,投运后取得了良好的效果。 The technical characteristics of high -frequency power converters and sectionalization are described. The technologies were aimed at high gas velocity in the electric field of electrostatic precipitators at No. 8 125 MW unit at Guizhou HuaDian Zunyi Power Plant. The electrostatic precipitators were rebuilded on mechanical configuration and electrical performance to improve the operation voltage and current without increasing the cross - sectional area. After the reformation the emission was achieved excellent effect.
作者 章华熔
出处 《电力环境保护》 2008年第4期45-48,共4页 Electric Power Environmental Protection
关键词 高频电源 分区供电 窄极距 高风速 high- frequency power sectionalization narrow polar distance high gas velocity
  • 相关文献

参考文献11

  • 1Sproull, Wayne T. Collecting high resistivity dusts and fumes [ J ]. In-dustrial and Engineering hemistry, 1955,47(5 ) :940 -944.
  • 2郭俊.中国环保产业协会电除尘委员会第十一届全国电除尘学术会议论文集[C].郑州:2005.
  • 3刘后启 等.电收尘器[M].北京:中国建筑工业出版社,1987..
  • 4陈康元.电除尘器振打清灰技术.电除尘及气体净化,1998,(1):22-26.
  • 5舒宜.燃煤锅炉飞灰特性研究[J].动力工程,1990,10(3):15-21. 被引量:12
  • 6Anatol J, Andrzej K, Tadeusz C. Modem electrostatic devices and methods for exhaust gas cleaning[ J ]. Journal of Electrostatics,2007, (65) :133 - 155.
  • 7Licht W. Air pollution control engineering: 2nd Edition [ M ]. New York : Marcel Dekker Inc, 1998.
  • 8OglesbyS NicholsGB 谭天祐译.电除尘器[M].北京:水利电力出版社,1983.30-51.
  • 9王洪礼.最新电除尘器的选型安装和运行及其技术应用适用手册[M].北京:中国机械工业出版社,2006.
  • 10龚立贤.电除尘器在火力发电厂的应用[J].热机技术,2000(4):6-12. 被引量:2

二级参考文献4

共引文献55

同被引文献40

引证文献1

二级引证文献2