摘要 本文就机械通风作业中的温差、单位通风量以及通风时机的把握对通风效果的影响进行了分析和讨论。结果表明:通风时间和温差呈双曲线规律变化,温差小于8℃后通风时间增加显著;风机轴功率和通风总能耗随单位通风量的变化分别按k2.3和k1.3的指数规律变化;合理选择通风时机可以明显提高通风效果。 This study aimed to analyze the effects on aeration by the difference in temperature between grain and air, airflow rate and opportunity of operation.The results showed that the change of aeration time is relative to the difference in temperature in a pattern of hyperbolic curve. When the difference in temperature is smaller than 8℃, the aeration time increases rapidly; The axle power and the total energy consumption change in a form of positive exponent curve in which the exponents are k2.3 and k1.3 respectively when the difference in temperature altesr; The rational selection for opportunity of operation can remarkably raise the effect of aeration.
出处 《食品科学》 EI CAS CSCD 北大核心 2008年第8期659-662,共4页 Food Science
基金 "十一五"国家科技支撑计划项目(2006BAD08B05) 江苏省高技术计划(农业)项目(BG2007340)
关键词 机械通风 单位通风量 温差 aeration airflow rate difference in temperature
  • 相关文献

参考文献3

二级参考文献9

  • 1K.J.Hellcang, Lesie Backer et al. Dry Grain Aeration Systems Design Handbook. Midwest Plan Service.Ames,IA.1999
  • 2Shlomo Navarro, Ronald Noyes et al. The Mechanics and Physics of Modern Grain Aeration Management.CRC Press LLC.2002
  • 3中华人民共和国粮食行业标准,LS/T 1202-2002.储粮机械通风技术规程.国家粮食局,2002
  • 4Lope G.Tabil, Ryan White et al. Airflow Resistance of Sugar Beets. ASAE Paper No.99-6059,St. Joseph, MI. 1999
  • 5陆耀庆.供暖通风设计手册.北京:中国建筑工业出版社,1987.985-987
  • 6李庆宜.通风机.北京:机械工业出版社,1981.233-237
  • 7左进良.储粮通风技术.北京:轻工业出版社,1990.107-109
  • 8王立,魏清国.粮食通风与干燥.南京:江苏科学技术出版社,1992
  • 9严以谨,王金水,苏云平.机械通风储粮技术.郑州:河南科学技术出版社,1996

共引文献36

同被引文献81

引证文献14

二级引证文献43

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部